Hoymiles Microinverter Installation Map
Please Make N for North
1
A
B
C
D
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
COLUMN
ROW
AP040228 V1.3
Customer Information:
DTU Serial Number
Azimuth:
Tilt:
Panel type:
Step 5. Connect PV Modules
Step 6. Energize the System
A)
Turn on the AC breaker of the branch circuit.
B)
Turn on the main AC breaker of the house.
Your system will start to generate power in
about two minutes.
A)
Mount the PV modules above the
microinverter.
B)
Connect the PV modules’ DC cables to the
DC input side of the microinverter.
Step 4. Create an Installation Map
A)
Peel the removable serial number label
from each microinverter (the position of
the label is shown as below).
B)
Affix the serial number label to the
respective location on the installation map.
*Note: L: Brown wire
N: Blue wire
G: Yellow/Green wire
Please use a 12 AWG cable as the AC end cable.
Product information is subject to change without notice. (Please download reference manuals at www.hoymiles.com.)
Step 3. Connect AC End Cable
Region: Australia/New Zealand AP040269 V1.2 © 2022 Hoymiles Power Electronics Inc. All rights reserved.
Step 7. Set Up the Monitoring System
Refer to the DTU User Manual, DTU Quick Installation Guide, and
Quick Installation Guide for S-Miles Cloud to install the DTU and set
up your monitoring system.
A)
Make the AC end cable.
1. Separate the AC port into 3 parts.
2. Insert the AC cable through Part 3 into Part
2, and complete the wiring for the L, N and
Ground inside the AC port in Part 1.
Coated with solder
Part 1
Part 2
Part 3
AC Cable
Part 1
Part 2
3. Plug the AC port Part 2 into Part 1 once the
wiring is complete, and then screw on Part
3 to complete the AC extension cable.
Part 3
B)
Connect the AC end cable to the AC male
connector from the first microinverter to
complete the circuit.
C)
Connect the other side of the AC end cable to the distribution box, and wire it to the local grid network.