Hoymiles DTU-Pro Скачать руководство пользователя страница 3

© 2021 Hoymiles Power Electronics Inc. All rights reserved.

02

Single-phase Microinverter User Manual

1. Important Safety Information

1.1  Read This First

This manual includes important instructions for installing and maintaining the Hoymiles Data  Transfer Unit
(DTU-Pro).

1.2  Safety Instructions

Symbol

Usage

Indicates hazardous situations that can result in deadly electric shock hazards, 
other serious physical injuries, or fire hazards.

Indicates directions that must be fully understood and followed in their entirety 
to avoid potential safety hazards including equipment damage or personal 
injury.

Indicates that the described operation must not be carried out. The reader 
should stop, use caution, and fully understand the operations explained before 
proceeding.

• Note that only professionals may install or replace DTU.

• Do not try to repair the DTU without approval from Hoymiles. If the DTU is damaged, send the DTU back

to your installer for repairing/replacement. Disassembling the DTU without approval from Hoymiles will
invalidate the remaining warranty period.

Read all instructions and warnings on the technical specifications carefully.

• Do not use Hoymiles products in a way that is not suggested by the manufacturer. Doing so may cause

death or injury to persons or damage to the equipment.

1.3  User

This manual is intended for use by professional installation and maintenance personnel only.

1.4  Support and Contact Information

If you have technical queries concerning our products, contact your system installer or distributor. If further 
support is required, contact Hoymiles’ support at this link.

• www.hoymiles.com

• Hoymiles Technical Service Center: [email protected]

1.5  Other Information

Product information is subject to change without notice. The user manual will be frequently updated. refer to 
the Hoymiles official website at www.hoymiles.com for the latest version.

Содержание DTU-Pro

Страница 1: ...Open Energy for All Single phase Microinverter USER MANUAL DTU Pro Region Global V202105 hoymiles com...

Страница 2: ...rm 03 3 Interface Layout 03 3 1 Interface Layout 03 3 2 Export Management Function RS485 port 04 3 3 Remote Active Power Control RS485 port 04 3 4 DRM Port 05 3 5 Local Installation Assistant 05 4 DTU...

Страница 3: ...the DTU without approval from Hoymiles If the DTU is damaged send the DTU back to your installer for repairing replacement Disassembling the DTU without approval from Hoymiles will invalidate the rema...

Страница 4: ...onitoring Platform The DTU communicates wirelessly with the microinverters via 2 4 GHz Proprietary RF Nordic and collects the operation data of the system Meanwhile the DTU connects to the Internet vi...

Страница 5: ...tain value Type 3 Production and Consumption Monitoring enable to measure the PV generation with high accuracy c Installation Diagram PV Module PV Module Hoymiles MI 600 Hoymiles MI 600 Solar Local Lo...

Страница 6: ...traints from other active DRMs 3 5 Local Installation Assistant Local Installation Assistant is a new function integrated with DTU Pro Download the Installer App for installer distributor use only bef...

Страница 7: ...ation conditions described in both the DTU and microinverter manuals The distance between the microinverter and the DTU needs to be within the required range 4 2 Basic Conditions Required Before insta...

Страница 8: ...ll optional 7 Connect to the Internet 8 Start procedure 9 Normal operation 4 5 Preparation A Download the Hoymiles Installer App B Check the box for following items Hoymiles DTU Pro Two Antennas Adapt...

Страница 9: ...tenna at support hoymiles com Step 2 Choose an installation location Install on the top floor to increase signal strength Install near the center of the PV array Install at least 0 5 m above the groun...

Страница 10: ...nnas are perpendicular to the table a Plug in the power adapter to power the DTU b Set up with Internet c Use the smartphone tablet to open the Installer App and login Locate Me on the bottom of the p...

Страница 11: ...2021 Hoymiles Power Electronics Inc All rights reserved 10 Single phase Microinverter User Manual...

Страница 12: ...allation map A Peel the serial number label as circled below from the DTU and place it on the installation map B Complete the system information of the installation map as shown below NSEW circle one...

Страница 13: ...ete F Press Add DTU SN scan the DTU SN or you can manually input the SN and press Next after this is complete G Press Start pairing and choose the angle and tilt based on the installation site H Scan...

Страница 14: ...by installer in the previous step Section 6 Step B and press Login c Customers will be able to view all details once the data starts to upload Normally it will take around 30 minutes for the first da...

Страница 15: ...2021 Hoymiles Power Electronics Inc All rights reserved 14 Single phase Microinverter User Manual 9 View Phone App Download mobile phone app and view plant information...

Страница 16: ...n Microinverter communication Fault state LED States LED Indicator Status Description All Firmware upgrading Starting up DTU power on DTU power off DTU is communicating with the S Miles Cloud Hoymiles...

Страница 17: ...pp Local app Power Supply Type External plug in adapter Adapter input voltage frequency AC 100 to 240 V 50 or 60 Hz Adapter output voltage current 5 V 2 A Power consumption 2 5 W typical 5 W maximum M...

Отзывы: