Страница 1: ...Version 2 1 August 2020...

Страница 2: ...The DTU 4 2 3 The Hoymiles Monitoring Server 4 3 DTU Installation 5 3 1 System Capacity 5 3 2 Basic Conditions Required 5 3 3 Dimensions 5 3 4 Interface Layout 5 3 5 Local Install Assistant 6 3 6 Sys...

Страница 3: ...ng so may cause death or injury to persons or damage to equipment 1 3 User This manual is only for professional installation and maintenance personnel to use 1 4 Support and Contact Information If you...

Страница 4: ...microinverters rank into the first class of the world s Microinverter industry 2 2 The DTU The DTU is the key component in Hoymiles microinverter system It works as the communication gateway which op...

Страница 5: ...TU can monitor may be reduced 3 2 Basic Conditions Required Before installing the DTU ensure the site meets the following requirements l The straight distance between DTU and Microinverter shall be le...

Страница 6: ...glance of eyes B Add the Connection status which will display the signal strength between each MI with connected DTU so that installer can adjust the DTU installation location accordingly This functio...

Страница 7: ...te reduction increases with the amount of reinforcement 10 90 Metal Up to 100 Therefore the DTU shall be placed as close to the microinverters as possible at the site to ensure good communication betw...

Страница 8: ...te G Click Start binding and choose the angle and tilt base on the installation H Scan the Microinverter ID or you can manually input the ID and click the tick after completing each ID input Press Fin...

Страница 9: ...system is energized and the DTU detects the microinverters you need to complete the installation map A Peel the serial number label from the DTU and place it on the installation map B Complete system...

Страница 10: ...from there 9 LED indicator working status description Red Light Description Flashes every 1 second No SIM Card Flashes every 0 5 seconds DTU disconnect with server Blue Light Description Flashes ever...

Страница 11: ...Direct power supply Display LED indicator light Others Standard EN60950 EN61000 3 2 EN61000 3 3 FCC 15B 15C Indicator Status Description Solution Red LED Flesh in Red every 1 second No SIM Card l Che...