2

HOWARD INTERACTIVE KIOSK INSTALLATION GUIDE

TABLE OF CONTENTS

MIPS and Android ..........................................................................3 
     MIPS Open and Close ...............................................................3 
     MIPS File Storage Path ..............................................................4
     Basic Settings for Android .........................................................4
MIPS Function Description .............................................................5 
     Body Temperature Setting ........................................................6 
     Identification Parameter Settings ..............................................7
     Start Up Settings .......................................................................8
     Application Information Settings ...............................................8
     Relay Settings ............................................................................9
     Other Settings ............................................................................9
     Face Data Entry .......................................................................10
     Face Database ........................................................................10
     Pass Record ............................................................................11
     Application Information ...........................................................11

Содержание ArrivScan micro

Страница 1: ...FOR SUPPORT CALL 888 323 3151 1 HOWARD ARRIVSCAN MICRO QUICK START MANUAL ...

Страница 2: ...PS File Storage Path 4 Basic Settings for Android 4 MIPS Function Description 5 Body Temperature Setting 6 Identification Parameter Settings 7 Start Up Settings 8 Application Information Settings 8 Relay Settings 9 Other Settings 9 Face Data Entry 10 Face Database 10 Pass Record 11 Application Information 11 ...

Страница 3: ...eft mouse button to confirm enter click the right mouse button to cancel exit and click the middle mouse button to pop up the interface MIPS OPEN AND CLOSE OPEN MIPS is started by default Face recognition and temperature measurement can be started after switching on the power CLOSE In the MIPS application interface connect the mouse through the USB interface double click the right button repeat tw...

Страница 4: ...The specific path is Internal Memory viplmg BASIC SETTINGS FOR ANDROID LANGUGES AND INPUT Enter the setting interface of the Android system and select language input After adding the target language drag the target language to the first priority and the system will automatically switch to the first priority language DATE AND TIME Enter the settings interface of the Android system and select date t...

Страница 5: ...ssword 123456 to open the Application Management interface which displays the current login state and five functions i e Application settings Face data entry Application information Pass record and Face database Enter the operation password Application settings interface Open the application management interface DEVICE NAME SETTING Custom device name ...

Страница 6: ...is set as 0 3 when the ambient temperature is lower than 25 C it is set as 0 3 ALARM THRESHOLD Set the alarm temperature threshold of the system and when the body temperature of the detected person exceeds the threshold the system will send an alarm TEMPERATURE ALARM Open means open temperature alarm Turn off means turn off the temperature alarm FAN Fan switch is behind the detector MASK DETECTION...

Страница 7: ... BODY Open means open living body dynamic detection Close means to close the dynamic detection living body By default VOLUME SETTING Set the alarm volume In case of invalid situation please exit the app and adjust the volume in the Settings interface of the Android system Identification parameter settings interface STRANGER MODE Open will automatically compare information in the face database if n...

Страница 8: ... the cycle If not the application will be opened automatically APPLICATION THREAD DAEMON The application will take priority in system memory APPLICATION INFORMATION SETTINGS You can choose to hide or display If you choose to hide the application information will not be displayed in the temperature measurement interface and if you choose to display the application information will be displayed in t...

Страница 9: ...pening MODE 2 Low efficiency auto close mode the relay will automatically close after opening DELAY The response time of auto close shutdown is delayed close OTHER SETTINGS Temperature module firmware can be upgraded in this interface Setting callback setting URL IP and port number Connected to LAN APPLICATION INITIALIZATION Clear device registration information face database traffic records and a...

Страница 10: ...el face data as a comparison basis for face recognition The corresponding generated image data is stored locally in the Android system explorer The specific path is Internal Memory viplmg FACE DATABASE This option is used to manage face database information and can be used to add and delete face data ...

Страница 11: ...rd all visitors generate a picture file and store it locally in the Android system explorer The specific path is Internal Memory currentlmg This data can be exported to external storage via USB APPLICATION INFORMATION This option displays application information for viewing ...

Страница 12: ... Free 1 888 912 3151 Customer Support Toll Free 1 888 323 3151 Technical Support We provide FREE telephone technical support 24 7 excluding US holidays for as long as you own your Howard product Our friendly US based team of experts will answer your questions about the product hardware setup or installation and with telephone hold times of typically less than 1 minute For technical support call 88...

Отзывы: