8
4 209 973 / 00
Fault investigation
The inlet and outlet screens and the evaporator must be checked for
dirt regularly, and cleaned when necessary.
Corrective action
• See fault display
• Replace fuse
• Switch on main switch
• Reset safety thermostat
• Replace
• Replace
• Replace
• Turn on
• Check standby, replace
• See fault display
• Clean
• Install
• Fill
Cause
• See fault display
• No power to the plug
• Main switch switched off
• Overheating
• Electrical connection defective
• Electrical connection defective
• Pump defective
• Pump blocked
• Boiler not in standby position
• High-pressure fault
• Condensate drainage blocked
• No drainage siphon installed
• No water in drainage siphon
Fault
Alarm signal in display
Electrical fault
no display
Electrical heating does not heat
up, although switched on
Additional heating does not heat up,
although it is switched on
Fault No. 5 or 6
Condensate leak during operation
Smell
You can minimise the risk of a fault
occurring by signing up to a service
contract. If despite this something
goes wrong, go through the
fault checklist. Make sure that you
have adhered to the instructions in
the manual. If nevertheless
the fault cannot be eliminated,
please contact your Hoval
customer service.
Typ CombiVal WP-VT (2141)
Fault investigation