4 Operation
User reference guide
6
Bela08+16I3 + Belar08+16I3
Hoval BelariaSRM and Hoval Belaria compact SRM
4P330441-1 – 2012.11
4 211 876 / 00 – 11/12
You can…
Location
Check
which space operation mode is
currently used
.
Home pages:
▪ Room temperature
▪ Leaving
water
temperature (main
+ additional)
Set
the space operation
mode
.
Menu structure
Restrict
when
automatic changeover
is
possible.
To determine if a heating/cooling heat pump
model is installed
1
Press
to go to the menu structure.
2
Check if [4] Operation mode is listed. If so, a heating/cooling
heat pump model is installed.
To check which space operation mode is currently
used
1
Go to one of the following the home pages:
▪ Room temperature home page (Room)
▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)
2
Check the status icon:
If you see…
Then…
Operation mode = heating.
Unit is NOT heating up your space.
However, the DHW tank can be
heating up.
Operation mode = heating.
Unit is heating up your space at this
moment.
Operation mode = cooling.
Unit is NOT cooling down your space.
However, the DHW tank can be
heating up.
Operation mode = cooling.
Unit is cooling down your space at this
moment.
To set the space operation mode
1
Go to [4]:
> Operation mode.
2
Select one of the following and press
:
If you select…
Then the space operation mode is…
Heating
Always heating mode.
Cooling
Always cooling mode.
Automatic
Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
takes monthly restrictions into account.
Note: Automatic changeover is only
possible under certain conditions.
To restrict when automatic changeover is possible
1
Go to [7.5]:
> User settings > Allowed operation mode.
2
Select a month and press
.
3
Select Heating only, Cooling only or Heating/Cooling, and press
.
Typical automatic changeover restrictions
When
Restriction
During cold season.
Example: October, November, December,
January, February and March.
Heating only
During warm season.
Example: June, July and August.
Cooling only
In-between.
Example: April, May and September.
Heating/Cooling
4.4.3
Controlling the temperature
About controlling the temperature
Depending on the system layout and installer configuration, you use
a different temperature control:
▪ Room thermostat control (linked or NOT linked)
▪ Leaving water temperature control
▪ External room thermostat control
To determine which temperature control you are using
(method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are using
(method 2)
If you have 2 user interfaces, perform the following procedure on the
user interface at the indoor unit.
1
Press
multiple times to switch between home pages, and
check if the additional leaving water temperature home page
(LWT add) is available:
If …
Then you have…
Available
A main zone and an additional
zone
NOT available
Only a main zone
Typical additional leaving water temperature home page:
User profile = Basic
User profile = Detailed
45°C
1 5 : 2 0
D e s i r e d t e m p e r a t u r e
Mon
LWT add
45°C
1 5 : 2 0
2 2 : 0 0
D e s i r e d t e m p e r a t u r e
Mon
LWT add
Mon
2
Go to [6]:
> Information.
3
Press
for more than 5 seconds.
Result:
The user permission level switches to Adv. end user.
Additional information is displayed and "+" is added to the menu
title.
4
Check the following:
If…
Then the temperature control is…
Main zone
Additional zone
(if any)
Room temperature is
listed under:
[6.1]:
> Information
> Sensor information
Room thermostat
control.
Go to next step to
check if leaving
water set point and
room temperature
set
point
are
linked.
External room
thermostat control.
Содержание Belaria compact SRM 11-16/260