background image

4 Operation

 

User reference guide

6

Bela08+16I3 + Belar08+16I3

Hoval BelariaSRM and Hoval Belaria compact SRM

4P330441-1 – 2012.11

4 211 876 / 00 – 11/12

You can…

Location

Check

 which space operation mode is

currently used

.

Home pages:

▪ Room temperature

▪ Leaving 

water

temperature  (main
+ additional)

Set

 the space operation 

mode

.

Menu structure

Restrict

 when 

automatic changeover

 is

possible.

To determine if a heating/cooling heat pump
model is installed

1

Press 

 to go to the menu structure.

2

Check  if  [4]  Operation  mode  is  listed.  If  so,  a  heating/cooling
heat pump model is installed.

To check which space operation mode is currently
used

1

Go to one of the following the home pages:
▪ Room temperature home page (Room)
▪ Main leaving water temperature home page (LWT main)
▪ Additional leaving water temperature home page (LWT add)

2

Check the status icon:

If you see…

Then…

Operation mode = heating.

Unit  is  NOT  heating  up  your  space.
However,  the  DHW  tank  can  be
heating up.
Operation mode = heating.

Unit  is  heating  up  your  space  at  this
moment.
Operation mode = cooling.

Unit is NOT cooling down your space.
However,  the  DHW  tank  can  be
heating up.
Operation mode = cooling.

Unit is cooling down your space at this
moment.

To set the space operation mode

1

Go to [4]: 

 > Operation mode.

2

Select one of the following and press 

:

If you select…

Then the space operation mode is…

Heating  

Always heating mode.

Cooling  

Always cooling mode. 

Automatic  

Automatically changed by the software
based on the outdoor temperature
(and depending on installer settings
also the indoor temperature), and
takes monthly restrictions into account.

Note:  Automatic  changeover  is  only
possible under certain conditions.

To restrict when automatic changeover is possible

1

Go to [7.5]: 

 > User settings > Allowed operation mode.

2

Select a month and press 

.

3

Select Heating only, Cooling only or Heating/Cooling, and press

.

Typical automatic changeover restrictions

When

Restriction

During cold season.

Example: October, November, December,
January, February and March.

Heating only  

During warm season.

Example: June, July and August.

Cooling only  

In-between.

Example: April, May and September.

Heating/Cooling  

4.4.3

Controlling the temperature

About controlling the temperature

Depending on the system layout and installer configuration, you use
a different temperature control:

▪ Room thermostat control (linked or NOT linked)

▪ Leaving water temperature control

▪ External room thermostat control

To determine which temperature control you are using
(method 1)

Check the installer settings table filled in by the installer.

To determine which temperature control you are using
(method 2)

If you have 2 user interfaces, perform the following procedure on the
user interface at the indoor unit.

1

Press 

 multiple times to switch between home pages, and

check  if  the  additional  leaving  water  temperature  home  page
(LWT add) is available:

If …

Then you have…

Available

A main zone and an additional
zone

NOT available

Only a main zone

Typical additional leaving water temperature home page:

User profile = Basic  

User profile = Detailed  

45°C

1 5 : 2 0

D e s i r e d   t e m p e r a t u r e

Mon

LWT add

45°C

1 5 : 2 0

2 2 : 0 0

D e s i r e d   t e m p e r a t u r e

Mon

LWT add

Mon

2

Go to [6]: 

 > Information.

3

Press 

 for more than 5 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu
title.

4

Check the following:

If…

Then the temperature control is…

Main zone

Additional zone

(if any)

Room temperature is
listed under:

[6.1]: 

 > Information

> Sensor information

Room thermostat
control.

 

Go  to  next  step  to
check  if  leaving
water set point and
room  temperature
set 

point 

are

linked.

External room
thermostat control.

 

Содержание Belaria compact SRM 11-16/260

Страница 1: ...4 Inneneinheit BelariaSRM 6 8 Inneneinheit BelariaSRM 11 16 Inneneinheit Belaria compact SRM 4 180 IE Belaria compact SRM 6 8 260 IE Belaria compact SRM 11 16 260 IE Subject to change 4 211 876 00 11...

Страница 2: ...the contact helpdesk number 21 7 Troubleshooting 21 7 1 Overview Troubleshooting 21 7 2 To check the error history 21 7 3 Symptom You are feeling too cold hot in your living room 21 7 4 Symptom The wa...

Страница 3: ...Detailed step by step instructions and background information for basic and advanced usage CD DVD in the box of the indoor unit Latest revisions of the supplied documentation may be available on the...

Страница 4: ...in the menu structure Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between displaying actual and offset values if applicable on...

Страница 5: ...n ON Then Room temperature control Main additional leaving water temperature control is automatically turned ON If you turn ON Then Main additional leaving water temperature control Room temperature c...

Страница 6: ...r settings Allowed operation mode 2 Select a month and press 3 Select Heating only Cooling only or Heating Cooling and press Typical automatic changeover restrictions When Restriction During cold seas...

Страница 7: ...Preset values and schedules on page 15 Leaving water temperature of the main zone To control the leaving water temperature of the main zone you can do the following You can Location Read out the desi...

Страница 8: ...18 C Desired temperature When you are away During the night Schedule 07 00 Comfort You are at home Desired temperature preset value Comfort heating 09 00 Eco You are away Desired temperature preset va...

Страница 9: ...eduled 20 C Advantage You save energy because you do NOT heat the room unnecessary and by the time you come home the room is warm again Using the leaving water temperature home pages main additional I...

Страница 10: ...to the DHW tank temperature home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode 4 5 2 Reheat mode In reheat mode t...

Страница 11: ...pump schedule to determine when to turn ON and OFF the pump When turned ON the pump runs and makes sure hot water is instantly available at the tap To save energy only turn ON the pump during periods...

Страница 12: ...tivate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW tank booster mode You can use the DHW tank booster mode to immediately start heating up the water to...

Страница 13: ...re on page 6 Using holiday mode typically consists of the following stages 1 Configuring the holiday for one of the following situations Situation Then You stay at home during your holiday You have to...

Страница 14: ...an do the following 1 Deactivate the holiday mode 2 When you go away again activate the holiday mode again Advantage You do NOT have to change your schedule or holiday configuration easy 4 6 3 Reading...

Страница 15: ...Function lock Locks a specific function to prevent people from changing its settings Possible function locks Lock If active people cannot Room On OFF Turn ON or OFF the room temperature control LWT On...

Страница 16: ...c hot water tank Booster heater allowance Program when the booster heater can operate Example Only allow the booster heater to operate during the night Control Possible actions Quiet mode Program when...

Страница 17: ...ned 1 User defined 2 or User defined 3 and press 3 Change the name and press Example MyWeekSchedule 4 7 4 Predefined schedules Room temperature leaving water temperature main Desired temperature Prese...

Страница 18: ...0 11 12 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desi...

Страница 19: ...tors Operation modes Running hours Version Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Ope...

Страница 20: ...c hot water control A 4 Setting Default Fill in Setpoint mode 2 Scheduled only Setpoint readout type 0 Temperature Maximum setpoint Depends on model INFORMATION It is recommended NOT to use the select...

Страница 21: ...ation Error handling Contact helpdesk number 7 Troubleshooting 7 1 Overview Troubleshooting If a malfunction occurs is displayed on the home pages You can press to display more information about the m...

Страница 22: ...ble for a certain product or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain...

Страница 23: ......

Страница 24: ...sterreich Hoval Gesellschaft mbH Hovalstrasse 11 A 4614 Marchtrenk Telefon 050 365 0 Telefax 050 365 5005 www hoval at info hoval at Marchtrenk Hovalstrasse 11 4614 Marchtrenk Tel 050 365 5550 Fax 050...

Отзывы: