background image

27536-0-0610

Page 48

HOUSEWARMER is a registered trademark of 

Empire Comfort Systems Inc.

www.housewarmerproducts.com

EMPIRE

EMPIRE

Comfort Systems

Manufactured for:

Empire Comfort Systems Inc.

918 Freeburg Ave. Belleville, IL  62220

PH: 877-459-1583

FAX: 877-459-0514

Содержание HWDV080BDVN-2

Страница 1: ...nual with the ap pliance Consumer Retain this manual for future reference Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO...

Страница 2: ...Location 14 Installation Overview 15 16 Interior Installation 17 20 Cutting the Vent Tubes 21 22 Exterior Installation of the Venting 23 25 Reassembly and Resealing Vent Air Intake System 26 28 Insta...

Страница 3: ...IRECT VENT HEATER INSIDE WALL MOUNTING PLATE ATTACHED ON BACK INLET OUTLET TUBES INSTALLATION TEMPLATE TEMPLATE FOR HWDV080 ON REVERSE SIDE OUTSIDE WALL MOUNTING PLATE VENT CAP VENT KIT HARDWARE PACKE...

Страница 4: ...LE WRENCH CAULKING PHILLIPS SCREW DRIVER TAPE MEASURE DRILL SAW FURNACE CEMENT HARDWARE PACKETS PLASTIC TOGGLE 6 10 X 1 SLOTTED HEX HEAD SCREW 6 NYLON WASHER 2 10 X PHILLIPS HEX HEAD SCREW 3 10 X 2 HE...

Страница 5: ...16 25 3 16 WIDTH 18 5 16 22 5 16 DEPTH 8 7 8 9 3 8 NET WEIGHT LBS 33 5 45 5 MAX GAS CONSUMPTION 8 000 Btu hr 18 000 Btu hr SAFETY DEVICES Safety valve thermocouple NOTE This direct vent wall furnace...

Страница 6: ...27536 0 0610 Page 6 UNIT DIMENSIONS MAKE SURE THAT APPLIANCE IS SUITABLE FOR THE GAS SUPPLY AVAILABLE NATURAL GAS OR PROPANE LP...

Страница 7: ...person Heater should be inspected be fore use and at least annually by a qualified service person More frequent cleaning may be required due to ex cessive lint from carpeting bedding material etc It i...

Страница 8: ...trailer or area Finally let the service man and firefighters check for escaped gas Have them air out the area before you return Properly trained LP Gas service people should repair the leak then chec...

Страница 9: ...G The nearest point of the vent cap should be a minimum horizontal distance of six 6 feet 1 8 m from any pressure regulator In case of regulator malfunction the six 6 feet 1 8 m distance will reduce t...

Страница 10: ...r as required in accordance with the aboveprovisionsshallcomplywithNFPA720andbeANSI UL 2034 listed and IAS certified 3 SIGNAGE Ametal or plastic identification plate shall be per manently mounted to t...

Страница 11: ...supply inlet to building or the combustion air inlet to any other appliance 6 inches 152 mm for appliance 10 000 Btuh 3 kW 9 inches 229 mm for appliances 10 000 Btuh 3 kW and 50 000 Btuh 15 kW 12 inc...

Страница 12: ...outside wall The gas line opening should be made at this time Location of the opening will be determined by the position of floor joists and the valve and union used for servicing Note Never use plast...

Страница 13: ...The minimum distance from the center of the vent cap to the nearest outside corner or obstruction is 24 610 mm 5 The minimum wall depth is 4 1 2 114 3 mm and the maximum is 12 304 8 mm The use of tube...

Страница 14: ...e on the wall Also refer to Figure 3 for positioning the furnace on wall and for locating gas line connection WALL MOUNTING PLATE MIN 4 MAX 12 CASING FRONT PANEL To remove pull out at top and lift up...

Страница 15: ...ting system must be properly installed to insure proper and safe operation The venting system must also be properly re installed and re sealed to insure proper and safe operation INSTALLATION OVERVIEW...

Страница 16: ...Read the installation instructions thoroughly before cutting or drilling any holes for installation Warning Do not remove any rating plates attached to the unit CLEARANCES TO COMBUSTIBLES Allow clear...

Страница 17: ...hole onto the wall Mark the six 6 wall mounting plate screw holes onto the wall The size of the gas inlet hole will depend upon the size of gas pipe coming into the unit See page 17 box 3 and page 18...

Страница 18: ...LOOR LINE MARKING FOR GAS INLET HOLE Remove the template from the wall after the holes are marked The hole location markings should be present on the wall 5 Drill a pilot hole inside of the traced cir...

Страница 19: ...4 wood screws to attach the wall mounting plate to the wall If installing onto drywall not into a stud anchors must be used 8 Push on bottom of casing door to open it Pivot and remove cas ing door Rem...

Страница 20: ...e installation template indications Following your city local and state codes attach the gas line to the unit CAUTION Grasp wrench on regulator when installing gas in let NOTE The gas line can come th...

Страница 21: ...LET TUBE AIR INLET TUBE MOUNTING PLATE SCREWS 3X LONG SCREWS 4X CAP NOTE Flue outlet tube and air inlet tube should be measured and cut to the proper length from the back of the unit to the outside wa...

Страница 22: ...outlet tube is placed as far as possible onto the collar of flue outlet Mark the 3 76 mm diameter flue outlet tube 2 7 8 73 0 mm beyond the mounting surface for the outside wall plate Remove 3 76 mm d...

Страница 23: ...he proper length from the back of the unit to the outside wall of the house There should be little to no venting showing on the outside of the house 4 10 x 2 SCREWS Place caulking not provided beneath...

Страница 24: ...ment not provided to 3 76 mm diameter flue outlet collar on combustion chamber and to 3 76 mm diameter collar on vent cap 3 DIA VENT CAP COLLAR FURNACE CEMENT 4 If installing onto vinyl aluminum or an...

Страница 25: ...allation of this Housewarmer product is complete Attach vent cap into the 3 76 mm diameter flue outlet tube Attach vent cap to outside wall mounting plate with 3 10 x 1 2 13 mm screws provided EXTERIO...

Страница 26: ...ounting plate Apply new caulking beneath the edge of the outside wall mounting plate Use additional caulking to correct uneven wall surface such as clapboard Attach 5 127 mm diameter air inlet tube on...

Страница 27: ...REASSEMBLY AND RESEALING VENT AIR INTAKE SYSTEM FLUE OUTLET TUBE COLLAR OF FLUE OUTLET 3 DIA VENT CAP COLLAR FURNACE CEMENT 4 If installing onto a vinyl sided exterior wall attach vinyl siding vent sh...

Страница 28: ...resealing vent air intake system is completed Attach vent cap into the 3 76 mm diameter flue outlet tube Attach vent cap to outside wall mounting plate with 3 10 x 1 2 13 mm screws provided REASSEMBL...

Страница 29: ...T HW125SCB 1 Removefrontpanelofheaterbyopening thenliftingonesideout then the other Be careful not to loose the white nylon washers on the front panel 2 Disconnect the power cord from the blower assem...

Страница 30: ...bilization tabs and attach with four 4 screws provided Note It is necessary to use all four 4 screws to tighten down the blower in order to reduce vibration noise 5 Insert power cord through the hole...

Страница 31: ...power cord to blower assembly 7 Attach ground wires from the blower and power cord to the blower mounting bracket 8 Slide fan control into the tabs on the right side of the chamber support INSTALLATIO...

Страница 32: ...ify that the plastic washers are still in place on the front panel when replacing it For replacement parts see Parts List on pages 42 and 43 and Parts View on page 44 STRAIN RELIEF INSTALLATION OF OPT...

Страница 33: ...during any pressure testing of that system at test pressures in excess of 1 2 psi 3 5 kPa BEFORE OPERATING APPLIANCE DO NOT RECESS INTO WALLS BOOKCASES ETC CHECK THE FOLLOWING BEFORE OPERATING APPLIAN...

Страница 34: ...of traffic and away from furniture and draperies 3 4 Do not spray any aerosol near heater when in operation Do not store these elements near appliance Do not place clothing or other flammable material...

Страница 35: ...be modified Do not operate this appliance if any parts have been removed for service 7 Do not place flammable elements on or near the heater BEFORE OPERATING APPLIANCE 6 Avoid blocking air inlet and...

Страница 36: ...cked for gas tightness by means of leak detector solution soapy water or an equivalent solution as applicable CAUTION Since some leak test solutions including soapy water may cause corrosion or stress...

Страница 37: ...ne Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depart ment C Use only your hands to push in or turn the gas control knob Never use tools If the knob will...

Страница 38: ...hnician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call a qualified service techni cian or gas supplier 10 Attention Gas control has an INT...

Страница 39: ...e flame Do not mistake it for an improper yellow flame The pilot flame is blue and goes toward the main burner and thermocouple horizontally A slight yellow tip on the flame is normal The pilot flame...

Страница 40: ...ualified personnel Cleaning of pilot burner As required Clogging of same To be performed by qualified personnel In case of doubt please check with our Customer Service Department Use soft dry cloth to...

Страница 41: ...iping according to installation instructions Difficulties in heating room A Incorrect heater size B Low gas pressure C Partially plugged injector A Contact Service Department for sizing room B Check w...

Страница 42: ...HAMBER 8 M155 M155 GASKET OBSERVATION HOLE 9 R1055 R1055 ELECTRODE AND WIRE 10 DV781 DV781 OBSERVATION HOLE COVER 11 R1122 R1122 WING NUT 12 TH275 24644 BURNER 13 R2256 R2256 THERMOCOUPLE 14 R2893 R28...

Страница 43: ...LATE OUTSIDE 40 24626 24626 VENT SHIELD 41 TH334 TH334 VENT CAP NOT SHOWN R1081 R1081 PILOT ORIFICE 014 NAT NOT SHOWN R1089 R1089 PILOT ORIFICE 009 LPG NOT SHOWN 24633 24633 HARDWARE PACKAGE HEATER NO...

Страница 44: ...27536 0 0610 Page 44 PARTS VIEW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41...

Страница 45: ...l number serial number type of gas and purchase verification information Your Rights Under State Law This warranty gives you specific legal rights and you may also have other rights which vary from st...

Страница 46: ...27536 0 0610 Page 46 SERVICE NOTES...

Страница 47: ...27536 0 0610 Page 47 SERVICE NOTES...

Страница 48: ...ER is a registered trademark of Empire Comfort Systems Inc www housewarmerproducts com EMPIRE EMPIRE Comfort Systems Manufactured for Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 PH...

Отзывы: