A

.

Purpose

HOUGHTON BELAIRE is designed to provide a comfortable environment inside a recreational vehicle or

caravan

.

B

.

Achieving effective heating

&

cooling

Many factors will affect the total heat load within the caravan and many factors can also affect the working

efficiency of the air-conditioner 

Before purchasing HOUGHTON BELAIRE air-conditioners

,

the user 

with

shall consult 

the caravan manufacturer to understand the total heat load of the caravan and to choose the correct air-conditioner for

the application

.

The following measures are very useful to reduce the heat load within a caravan or RV and improve the

performance of the air-conditioner.

Close all the doors

,

skylights and windows

,

draw the curtains and open the sunshade or awning

.

Adjust the caravan

s position to make sure the sunshade is on the southern side in the northern hemisphere or on

the northern side in the southern hemisphere

.

This will reduce the exposure to direct sunshine

.

Turn off unnecessary electrical appliances within the caravan to reduce the heat load.

Cook outside of the caravan when possible

.

Park the caravan in shade if possible

.

In case of exceptionally high temperatures

,

turn on the air-conditioner in advance during the morning

.

Adjust the set temperature of the remote control to prevent frequent starting or stopping of the unit

.

C

.

Condensation

When warm

,

moist air within the caravan meets with a cold surface

,

condensation water may be formed

.

This is also

known as

"

sweating

".

In this case

,

make sure the following measures are taken:

Close and seal all the doors

,

skylights

,

windows to reduce the entrance of warm moist air

.

Operate the inside fan on high fan speed

,

avoid low and auto fan speeds

.

During the operation of the air-conditioner

,

condensate water will be produced and allowed to drain onto the roof

.

This is normal

.

The amount of condensate water is a function of air humidity

.

High humidity inside the caravan will

result in more condensate being generated

.

Close doors

,

windows and hatches to reduce this to a minimum

.

Please note that losses or damage caused by the condensate water are not within warranty scope

.

D

.

Choosing and using a generator

HOUGHTON BELAIRE requires a mains quality AC power source for correct operation

.

If you decide to supply

power using a generator then you are strongly recommended to consult with the generator supplier to confirm

suitability and sizing of the generator for your application

.

Please note that losses caused to the product by the using of the generator are not within warranty scope

.

Содержание A3501

Страница 1: ...OWNERS MANUAL CARAVAN AIR CONDITIONER MODEL MODEL NUMBER SERIAL NUMBER DATE PURCHASED For your safety please read this manual carefully before using the product A3501 T3500 A3800...

Страница 2: ...s in this manual All the contents with this Prohibition logo are about the actions that shall be prohibited or else the air conditioner may be damaged or the user s personal safety may be endangered A...

Страница 3: ...Product Introduction 2 Packing List 3 Installation Guidance 4 10 11 Product Maintenance 16 Specifications 17 Exploded Diagram and Parts List 18 Trouble Shooting Guide 20 Circuit Diagram 21 Remote con...

Страница 4: ...rate the air conditioner Install the air conditioner in compliance with the instructions of this manual Incorrect installation methods or alteration of the product may cause damage to the product or p...

Страница 5: ...temperatures turn on the air conditioner in advance during the morning Adjust the set temperature of the remote control to prevent frequent starting or stopping of the unit C Condensation When warm m...

Страница 6: ...arge M8 washers 4 10 Truss head tapping screws ST4 10 8 11 Plenum screw ST4 2 19 pan head screws 4 12 6 1 2 4 5 6 3 7 8 9 10 11 12 Outlet air duct M8 x 120mm hex head bolts 4 Metal clamping bars 4 Cou...

Страница 7: ...ll be able to support the air conditioner s weight 45kg 99 lbs Minimum thickness of roof is 25mm 1 maximum thickness of roof is 85mm 3 3 8 If the roof s thickness is greater than 85mm 3 3 8 you can pu...

Страница 8: ...fan It s suggested to install 2 or more units on a caravan which is more than 7 meters long to achieve desired cooling effect Please confirm position of rooftop unit as per below drawing and check th...

Страница 9: ...lenum position Position of rooftop unit Moving direction of caravan Unit inch 14 3 16 14 3 16 21 1 8 21 15 16 26 3 4 19 6 1 8 Place the outdoor unit over the outlet gasket and adjust position to make...

Страница 10: ...outlet air down left and right way to be connected align and connect Truss head screw duct has the up and direction only one correctly please Connect the power Pay attention to the local wiring regul...

Страница 11: ...rs of the plenum mounting bracket Make sure fixing metal plates is 10mm distance from the plenum mounting bracket in order to adjust angle during installation Note Match the corresponding active neutr...

Страница 12: ...um mounting bracket Plenum assembly Fix the plenum assembly on the plenum mounting bracket with 4 provided pan head tapping screws Take out the return air filter and fix the plenum to the ceiling with...

Страница 13: ...nd then select fan function by pressing the MODE button Operate in low FAN medium FAN and high FAN in turn to check normal operation Select COOL mode adjust the set point temperature to three degrees...

Страница 14: ...11 C Temperature display Plenum display Touch screen key Mode display Remote control operation Standard remote control...

Страница 15: ...ess the key select the mode Press the key to select Low Medium High fan speeds The plenum will display and the indoor environment temperature Low Medium High COOL mode Press the key select the mode Pr...

Страница 16: ...e mode Press the up key to increase the room temperature Press the FAN key to select different speed and the plenum will display and the setting temperature AUTO mode Press the key select the mode Pre...

Страница 17: ...ey to set the desired time to turn the unit on 3 Press the SET TIME key until OFF shows on the lower right side of the clock and hour digit flashes Then press the HOUR MIN key and or key to set the de...

Страница 18: ...cted mode will cycle through OFF COOL FAN HEAT modes with each touch The set point temperature is 24 C with high fan speed The plenum display will show symbols for each function COOL DRY FAN HEAT AUTO...

Страница 19: ...cked for tightness 3 months after the first installation of the product These bolts should be regularly inspected every 12 months through out the air conditioner s life Product Maintenance Filter The...

Страница 20: ...16 26 3 4 39 5 16 Model Power supply Refrigerant charged Rated cooling capacity Rated heating capacity Input power for cooling W Input power for heating W Rated current for cooling A Rated current fo...

Страница 21: ...18 Exploded Diagram and Parts List...

Страница 22: ...19...

Страница 23: ...te control to set required temperature below the current room temperature The compressor will delay a re start for three minutes Check that the heating mode is selected and the plenum display shows Us...

Страница 24: ...21 A3501 Circuit Diagram A3800 Circuit Diagram T3500 Circuit Diagram Circuit Diagram...

Страница 25: ...V4 7330 2000 01...

Отзывы: