HotWire HWTH1 Скачать руководство пользователя страница 4

Menu #

Feature

Explanation

Factory 

default

Adjustment

(Press up & down buttons to adjust)

01

Mode/Sensor Selection

This thermostat is a combination model which

allows you to choose 3 different modes

A mode = Air Sensing Only (Has built in sensor)

AF mode = Air & Floor sensing

F mode = Floor sensing ( floor probe installed)

A

A / AF / F

02

Switching differential

The number of degrees difference before switching

The default is 1Deg C which means the stat will

switch the heating on 0.5DegC below the set 

temperature and will turn it off 0.5DegC above the 

set temperature.

With a 2 DegC differential the heating will switch

on 1 DegC below the set temperature and will 

switch off 1 DegC above the set temperature.

1 DegC

1 Deg C - 5 Deg C

03

Air Temp Calibration

This is to recalibrate the air temp if required

0DegC

-5 Deg C - + 5 Deg C

04

Floor Temp Calibration

This is the recalibrate the floor temperature if req

0DegC

- 5 Deg C - + 5 Deg C 

05

Temp Readout 

(AF mode only)

This gives you the option to show the Air Temp,

floor Temp or to show both Air & Floor at intervals

A

A = Show Air Temperature

F = Show Floor Temperature

A-F = Show Floor and Air Temperature in 5 sec 

intervals

06

Maximum Floor Temp

( AF Mode only)

This is to protect the floor surface

40 DegC

20 Deg C - 40 Deg C

07

Temperature For-

mat

This allows the temperature to be set to show 

Deg Celsius or Deg Fahrenheit

C

Deg C / Deg F

08

Clock Format

You can select the clock to show in either 12 

or 24 hour time

24

12 / 24

09

Frost Protection

This is to avoid your room temp going below 5 DegC

Off

On / Off

10

5+2 or 7 Day mode

 

This allows you to program either 5 days at once, 

then the 2 days of the weekend separately, 

or a full 7 days at the same time.

01

01 = 5 + 2 Day Programming

02 = 7 Day Programming

Hotwire

 

Thermostat

Technical Information

To access Menu settings,

1. Press Power button to turn off the thermostat.
2. Press and hold button Prog for three seconds to bring up the configuration menu. Now press Prog button to select each different menu number. 

Menu Settings

Page 2

Press       ,         starts flashing, press       

       or      to adjust the setpoint among a range of 5~30 deg C. (for floor mode, the

range will be 5~40 deg C).      

 Press        to confirm.

Press  and hold       to lock the buttons. A lock icon         will display.   

Vacation mode is used to drop the heating down to a minimum set temperature to ensure room stays damp free.

Press  and hold       to unlock the buttons.   The unlock icon              will display. 

220Vac     10%, 50/60Hz

DC 3 V (2 x 1.5 V AAA Alkaline batteries)

Accuracy: ±1

Set-point range: ambient 5~30 deg C

                              floor 5~40 deg C

Storage: -20~50 deg C 

Load Capability: <16 A, 220VAC

deg C

Wiring Diagram & Technical Specifications 

Additional Functions

+

230V AC

heating element

 Floor Sensor

Probe

  N   L

  M

This product should be installed by a qualified electrician.

 

Press this tab lightly back and simultaneously push the front 

panel upward to release it off the back plate. Wire up the 

Thermostat as per the wiring diagram below, then place the

back into the flushbox, and tighten it with the screws provided.

To replace the Thermostat,  slide the front panel downward

onto the back plate.

96
40

58

119

Vacation Mode Adjustment

Key Lock & Unlock

Dimensions & Installation

95

51

110

02

F