8.914-000.0, 8.917-410.0, 9.800-340.0 • Rev. 09/10
OPERA
T
OR’S MANU
AL
PRESSURE W
ASHER
8
Water
Inlet
SHUT DOWN AND CLEAN-UP
STEP 1:
Remove detergent suc-
tion tube from container and insert
into one gallon of fresh water. For
low pressure connect the black
detergent nozzle. Pull trigger on
spray gun and siphon water for one
minute.
STEP 2:
Turn off the motor.
STEP 4:
Disconnect the garden
hose from the water inlet on the
machine.
STEP 5:
Disconnect the high pres-
sure hose from high pressure
outlet.
STEP 6:
Engage the spray gun
safety lock.
STEP 3:
Press trigger to release
water pressure.
STORAGE
On-Off
Switch
High Pressure
Outlet
Safety
Latch
CAUTION
Pump Storage
CAUTION: Always store your pres-
sure washer in a location where the
temperature will not fall below 32° F
(0° C). The pump in this machine is
susceptible to permanent damage if
frozen.
FREEZE DAMAGE IS NOT COVERED BY WAR-
RANTY.
If you must store your pressure washer in a location
where the temperature is below 32° F, you can minimize
the chance of damage to your machine by draining your
machine as follows:
1. Stop the pressure washer and detach supply hose
and high pressure hose. Squeeze the trigger of the
spray gun to drain all water from the wand and
hose.
2. Restart pressure washer and let it run briefl y (about
5 seconds) until water no longer discharges from
the high pressure outlet.
In temperatures below 32° you may connect a bulkhead
fi tting to the bottom of a bucket then attach a garden
hose to siphon anti-freeze into the pump.