Chapter 15
Functions
Rev. 1.00.05
Subject to technical changes
15.8 Hot Runner Controller overall functions
Description
Hot runner controllers can be linked by CAN bus. Some functions (see below) can be
triggered and executed controller overall.
How it works
The hot runner controllers must be connected by CAN bus (see chapter
Each Hot Runner Controller must have its own unique
The parameter
[SP06]Offset zone numbering (page 193) must be set, that no zone
numbers are overlapping for the connected Hot Runner Controllers.
What good is it
Flexible use by combining several devices according to requirements.
Hot runner controllers can be combined and be used for tools with a high number of
zones.
Functional synchronization among each other.
Setting by
[SP06]Offset zone numbering (page 193)
For further details on parameters ([P***], [SP**], [CP**]) see Manual Parameters
hot-
control cDT+
.
Application example
2 hot runner controller (H1: 6 Zone, H2:12 Zone) are connected by CAN bus with
each other.
Set unique NodeID.
Setting:
[SP06] = 1 (on 1. hot runner controller H1) (Zone 1-6 first hot runner controller H1)
[SP06] = 7 (on 2. hot runner controller H2) (Zone 7-18 second hot runner controller
H2)
The function runs only for zones where the function is activated.
The function runs only for zones where the function is activated.
In leading zone operation for a defective sensor in zone 2 (on 1. hot runner controller
H1) [P023] = 9 can be set, that means zone 9 (zone 3 on 2. hot runner controller H2)
works as leading zone.
The function considers the zones in the particular device. Zone selection in the par-
ticular hot runner controller (Zone 1-6 in H1; Zone 7-18 in H2).
Other functions
All other functions for the zones are directly operated by Control&User Interface
CUI07 on each hot runner controller.
At correct connection and correct set-
ting of parameters the symbol (see
above) is shown in the header.
At existing CAN bus connection, but wrong
setting of parameters the symbol (see
above) is shown in the header.