Hotronix
®
POWER PLATEN
™
Quick Start Guide
Attaching to Press
Remove existing lower platen (1.1).
Leave Power Platen controller disconnected and to the side.
Insert Power Platen spindle and secure (1.2).
Attaching Controller to Power Platen
Once the platen is securely in place, attach the UNPLUGGED
controller by inserting the cable (2.1) and finger tightening
the clamp (2.2).
Now plug the Power Platen controller into a dedicated circuit.
Note:
Do not lay platen face down on any surface when hot.
Adjusting Temperature
Press the Mode Select button in the center of the Control Panel.
The (SET) and (TEMP) lights located next to the display will illuminate.
Press the (+) or (-) button to raise or lower the temperature setting.
The temperature can be set from 205°F (96°C) to 320°F (160°C).
The LED Display will show changes as you make them.
Pressure will be adjusted on the upper platen.
STAHLS‘ Europe GmbH
Dieselstraße 62
66763 Dillingen
Tel.: +49 (0) 68 31/97 33 - 0
www.stahls.eu
Note:
The temperature indicator will only display temperatures 200°F (93°C) and up.
Safety
2-Year-Warranty!
This product is designed for a specific and intended use; do not use this product for anything other than its intended use.
INFO:
Compatible with all Hotronix® Heat Presses, use Hotronix® Fusion™ with Power Platens only in Swing Mode.
For heat presses with a machine born-on date before 2014, call us please.
CAUTION: HOT
Do not remove until unit is completely cooled.
1.1
1.2
2.2
2.1
Digital
Display
Temperature
Indicator
Set
Indicator
Time
Indicator
Decrease
Increase
Mode Select
Caution:
When using Power Platen please use this settings to apply your transfer:
Heat Platen Transfer Press:
120°C
Power
Platen:
130°C
Please note the maximum pressure specification when using the Power Platen:
15x15 cm
max. 1 bar (light pressure)
Sleeve/Leg 15x50 cm
max. 2 bar (light to medium pressure)
28x28 cm & 40x50 cm
max. 2-3 bar (medium pressure)