Hotpoint HXQB 9.8LTI Скачать руководство пользователя страница 10

10

GB

PLEASE PHONE US TO REGISTER YOUR APPLIANCE  AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

Installation

The installation procedure is illustrated in the fi rst  pages 
of this manual. 
The installation must be done by a qualifi ed technician.

Electrical hook up

The mains voltage must match that given on the ratings 
label inside the hood itself. If the hood has a power plug, 
connect the hood to an easily accessible regulatory power 
socket. If it does not (direct connection to the mains), or the 
socket is not easily accessible, install a two-pole regulatory 
switch to enable total disconnection from the mains in case 
of category III overvoltage, as required by the installation 
regulations.

Caution!

 Always check that the mains cable is hooked 

up properly and check that it operates correctly before 
reconnecting the hood to the mains.

Air exhaust 

(for ducted units)

Connect the hood to a duct and wall exhaust hole of a 
diameter equal to that of the air outlet fl ange. Using a smaller 
diameter tube and exhaust hole reduces the extraction 
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of 
doing so.

!

 Use the shortest duct required to achieve the purpose.

!

 Use a duct with as few bends as possible

!

 Avoid suddenly changing the diameter of the duct.

!

 The duct must have as smooth an inner surface as 

possible.

!

 The duct must be made of regulatory material.

!

 Do not connect the hood to fl ues carrying combustion 

fumes from other equipment (boilers, chimneys, stoves, 
etc.).

!

 Observe the instructions of the competent authorities in 

relation to the air exhaust. The air being exhausted may not 
be exhausted into a wall cavity unless the cavity in question 
is specifi cally intended for this purpose.

!

 Equip the room with air intakes to prevent the hood creating 

suction pressure in the interior (this must not exceed 0.04 
mbar).

!

 The manufacturer is not liable for any consequences of 

failure to observe these instructions.

Filter or ducted?

!

 Your hood is supplied as a ducted unit.

If you wish to use it as a fi lter unit, you must install the proper 
ACCESSORY KIT.

Note:

 If supplied with the hood, the accessory active 

charcoal fi lter unit may already be installed.
Instructions for transforming the hood from the ducted to the 
fi lter version are given in this manual (see “Filter version”).

 Ducted version

The hood purifi es the air and expels it outdoors via an 
exhaust duct (dia. 150mm) connected to its outlet fl ange. 
The diameter of the exhaust tube must be equal to that of 
the outlet fl ange.

Caution!

 The exhaust duct is not supplied and must be 

purchased separately.
When routed horizontally, the tube must be angled slightly 
upwards (around 10°) to enable the air to be conveyed 
outdoors more easily. If the hood is fi tted with charcoal 
fi lters, they must fi rst be removed.

 Filter version

The hood purifi es the air and returns it to the room. This 
version of the hood requires installation of an accessory 
active charcoal fi lter unit.
This version requires an air defl ector, a reduction adapter 
and the charcoal fi lter/s. The top tube must have its air 
outlet slots uppermost.

Technical data

Model

Height 

(cm)

Width 

(cm)

Depth 

(cm)

dia. of 

exhaust tube 

(cm)

TBOX-GLASS 90cm

61-82

89.9

50

15/12

Please check the plate in order to verify the total 
absorption and the light absorption

LED 

Risk Group 1 according to Standard EN 62471

The model is in accordance with the following 
EU directives::
• “Low voltage” Directive 2006/95/EC (12-12-2006)
• “EMC” Directive 2004/108/EC (15-12-2004)
• UR Reference no. 66/2014 integrating Directive 
no. 2009/125/EC.

Reference standard:

•  EN 60704-2-13:2011; EN 60704-3:2006
•  EN 61591:1997; EN 61591:1997/A1:2006; EN 61591:1997/

A2:2011; EN 61591:1997/A11:2014

• EN 

50564:2011

Содержание HXQB 9.8LTI

Страница 1: ...i v a t e y o u r g u a r a n t e e HXQB 9 8LTI English Operating Instructions COOKER HOOD Contents Operating Instructions 1 Assembly 2 Warnings 8 Installation 10 TBOX GLASS controls 11 Maintenance and care 11 Troubleshooting 12 After Sales Service 13 Guarantee 14 ...

Страница 2: ...2 6x Ø 8 x 40 6x Ø 5 x 45 1x 2x 1x ø 150 125mm ø 150mm 1x 1x 6x Ø 3 5 x 9 5 2 3 4 5 ...

Страница 3: ...3 32 cm min 1A Ø150mm 1B Ø150mm Ø120mm Ø120 Ø150 Ø120mm Ø120 Ø150 Ø150mm ...

Страница 4: ...4 4 6 3 7 5 2 650 m m 550 m m x6 Ø 8 mm x6 x6 x2 5 m m ...

Страница 5: ...5 10 ø 120 ø 150 8 9 1 2 3 x2 x2 11 12 13 ...

Страница 6: ...6 ø 3 5 x 9 5 x2 14 15 ø 3 5 x 9 5 x2 ø 150 16 ...

Страница 7: ...7 ø 3 5 x 9 5 x2 A 18 21 17 19 20 ...

Страница 8: ...h to support the weight of the unit Caution Do not hook the unit up to its electrical power supply until the installation has been completed Before cleaning or servicing the unit disconnect it from the mains by pulling the power plug or disconnecting the main circuit breaker Alwayswearworkgloveswheninstalling and servicing the unit It is not intended for use by children or persons with sensory or ...

Страница 9: ... is not liable for any inconvenience damage or fire caused by the unit as a result of failure to observe the instructions given in this manual Caution The unit s accessible parts can get very hot when used with cooking equipment This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if ...

Страница 10: ...p the room with air intakes to prevent the hood creating suction pressure in the interior this must not exceed 0 04 mbar The manufacturer is not liable for any consequences of failure to observe these instructions Filter or ducted Your hood is supplied as a ducted unit If you wish to use it as a filter unit you must install the proper ACCESSORY KIT Note If supplied with the hood the accessory acti...

Страница 11: ...tor installation default red for filtering installation The installation type can be changed by pressing T7 cyclically with the consequent alternation of the LED colours Hood off The hood can be turned off manually by pressing the T1 button ON OFF If the timer is set the hood turns off automatically when the set time runs out Maintenance and care Caution Before cleaning or servicing the unit disco...

Страница 12: ...be treated as domestic waste but must be handed over to a sorting centre for electrical and electronic waste Dispose of it in accordance with local waste disposal regulations For further information on the handling recovery and recycling of this product contact the local authority domestic waste disposal service or the reseller from whom you purchased it Save energy and respect the environment Ple...

Страница 13: ...ssories We supply a full range of genuine replacement parts as well as accessory products that protect and hygienically clean your appliance to keep it looking good and functioning efficiently throughout its life UK 08448 225 225 Republic of Ireland 0818 313 413 www hotpointservice co uk Appliance Registration We want to give you additional benefits of Hotpoint ownership To activate your FREE 5 ye...

Страница 14: ...ulting from transportation improper use neglect or interference or as a result of improper installation Replacement of any consumable item or accessory These include but are not limited to plugs cables batteries light bulbs fluorescent tubes and starters covers and filters Replacement of any removable parts made of glass or plastic THE GUARANTEE WILL NOT APPLY IF THE APPLIANCE HAS BEEN USED IN COM...

Страница 15: ...GB 15 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 ...

Страница 16: ...GB 16 PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 195125388 00 05 2014 XEROX FABRIANO ...

Отзывы: