Installation

The installation procedure is illustrated in the fi rst  pages 
of this manual. 
The installation must be done by a qualifi ed technician.

Electrical hook up

The mains voltage must match that given on the ratings 
label inside the hood itself. If the hood has a power plug, 
connect the hood to an easily accessible regulatory power 
socket. If it does not (direct connection to the mains), or the 
socket is not easily accessible, install a two-pole regulatory 
switch to enable total disconnection from the mains in case 
of category III overvoltage, as required by the installation 
regulations.

Caution!

 Always check that the mains cable is hooked 

up properly and check that it operates correctly before 
reconnecting the hood to the mains.

Air exhaust 

(for ducted units)

Connect the hood to a duct and wall exhaust hole of a 
diameter equal to that of the air outlet fl ange. Using a smaller 
diameter tube and exhaust hole reduces the extraction 
capacity of the hood and also increases its running noise.
The manufacturer is not liable for any consequences of 
doing so.

!

 Use the shortest duct required to achieve the purpose.

!

 Use a duct with as few bends as possible

!

 Avoid suddenly changing the diameter of the duct.

!

 The duct must have as smooth an inner surface as 

possible.

!

 The duct must be made of regulatory material.

!

 Do not connect the hood to fl ues carrying combustion 

fumes from other equipment (boilers, TBOX-LUCEs, stoves, 
etc.).

!

 Observe the instructions of the competent authorities in 

relation to the air exhaust. The air being exhausted may not 
be exhausted into a wall cavity unless the cavity in question 
is specifi cally intended for this purpose.

!

 Equip the room with air intakes to prevent the hood creating 

suction pressure in the interior (this must not exceed 0.04 
mbar).

!

 The manufacturer is not liable for any consequences of 

failure to observe these instructions.

!

 The appliance may produce a slightly unpleasant odour 

when used for the fi rst time, due to the burning away of 
protective substances used during the manufacturing 
process.

Filter or ducted?

!

 Your hood is supplied as a ducted unit.

If you wish to use it as a fi lter unit, you must install the proper 
ACCESSORY KIT.

Note:

 If supplied with the hood, the accessory active 

charcoal fi lter unit may already be installed.

Instructions for transforming the hood from the ducted to the 
fi lter version are given in this manual (see “Filter version”).

 Ducted version

The hood purifi es the air and expels it outdoors via an 
exhaust duct (dia. 150mm) connected to its outlet fl ange. 
The diameter of the exhaust tube must be equal to that of 
the outlet fl ange.

Caution!

 The exhaust duct is not supplied and must be 

purchased separately.
When routed horizontally, the tube must be angled slightly 
upwards (around 10°) to enable the air to be conveyed 
outdoors more easily. If the hood is fi tted with charcoal 
fi lters, they must fi rst be removed.

 Filter version

The hood purifi es the air and returns it to the room. This 
version of the hood requires installation of an accessory 
active charcoal fi lter unit.
This version requires an air defl ector, a reduction adapter 
and the charcoal fi lter/s. The top tube must have its air outlet 
slots uppermost 

*

.

Technical data

Model

Height 

(cm)

Width 

(cm)

Depth 

(cm)

dia. of 

exhaust tube 

(cm)

TBOX-LUCE 60cm

61-82

59.8

50

15/12

TBOX-LUCE 90cm

61-82

89.9

50

15/12

Please check the plate in order to verify the total 
absorption and the light absorption

Power

Voltage

Cap

Dimensions

Halogen 25 W

2 x 25 W

230 V

G9

L40xØ14

Halogen 20 W

2 x 20 W

12 V

G4

L30xØ10

LED 

*

Risk Group 1 according to Standard EN 62471

The model is in accordance with the following 
EU directives::
• “Low voltage” Directive 2006/95/EC (12-12-2006)
• “EMC” Directive 2004/108/EC (15-12-2004)
• UR Reference no. 66/2014 integrating Directive 
no. 2009/125/EC.

Reference standard:

•  EN 60704-2-13:2011; EN 60704-3:2006
•  EN 61591:1997; EN 61591:1997/A1:2006; EN 61591:1997/

A2:2011; EN 61591:1997/A11:2014

• EN 

50564:2011

*

 Only available in certain models = 

Содержание HXB6.8LTI

Страница 1: ...uctions COOKER HOOD Contents Operating Instructions 1 Assembly 2 Warnings 9 Installation 11 TBOX LUCE controls 12 Maintenance and care 14 Troubleshooting 16 After Sales Service 18 Guarantee 19 P l e a...

Страница 2: ...2 6x 8 x 40 6x 5 x 45 4x 3 5 x 9 5 2x 1x 150 125mm 150mm 1x 2 3 4 5 1x...

Страница 3: ...3 32 cm min 1A 150mm 120mm 120 150 120mm 120 150 150mm 1B 150mm...

Страница 4: ...4 4 6 3 5 650 m m 550 m m x6 8 mm x6 x6 x2 5 m m 2 7...

Страница 5: ...5 10 11 8 9 1 2 3 x2 x2 12 120 150...

Страница 6: ...6 15 16 13 14 3 5 x 9 5 x2 150...

Страница 7: ...7 18 17...

Страница 8: ...e cooker hood must be at least 65 cm if the hood is installed over a gas cooktop 55 cm if the hood is installed over an electric cooktop If the installation instruction manual for the gas cooking appl...

Страница 9: ...y with the unit Never operate the unit without its grease filter installed NEVER use the hood as a support unless expressly instructed to do so Theroommustbeadequatelyventilated if the hood is used at...

Страница 10: ...is not liable for any inconvenience damage or fire caused by the unit as a result of failure to observe the instructions given in this manual Caution The unit s accessible parts can get very hot when...

Страница 11: ...of failure to observe these instructions The appliance may produce a slightly unpleasant odour when used for the first time due to the burning away of protective substances used during the manufactur...

Страница 12: ...fault red for filtering installation The installation type can be changed by pressing T7 cyclically with the consequent alternation of the LED colours Hood off The hood can be turned off manually by p...

Страница 13: ...at the product may not be treated as domestic waste but must be handed over to a sorting centre for electrical and electronic waste Dispose of it in accordance with local waste disposal regulations Fo...

Страница 14: ...Accessories We supply a full range of genuine replacement parts as well as accessory products that protect and hygienically clean your appliance to keep it looking good and functioning efficiently th...

Страница 15: ...e resulting from transportation improper use neglect or interference or as a result of improper installation Replacement of any consumable item or accessory These include but are not limited to plugs...

Страница 16: ...ASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24 195128201 00 11 2014 XEROX LODZ Indesit Company S P A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoi...

Отзывы: