Hotpoint G640N Скачать руководство пользователя страница 4

4

GB

PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24

Installation

!

 Before operating your new appliance please read this 

instruction booklet carefully. It contains important information 

for safe use, installation and care of the appliance.

!

 Please keep these operating instructions for future reference. 

Pass them on to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can 

become a choking or suffocation hazard (see Precautions 

and tips).

!

 The appliance must be installed by a qualified professional 

according to the instructions provided. Incorrect installation 

may cause harm to people and animals or may damage 

property.

!

 This unit may be installed and used only in permanently 

ventilated rooms in accordance with current national 

regulations. The following requirements must be observed:

•  The room must be equipped with an air extraction system 

that expels any combustion fumes. This may consist of 

a hood or an electric fan that automatically starts each 

time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is 

needed for combustion to occur normally. The flow of air 

must not be less than 2 m

3

/h per kW of installed power.

The air circulation system may 

take air directly from the outside 

by means of a pipe with an inner 

cross section of  at least 100 cm

2

the opening must not be vulnerable 

to any type of blockages.

The system can also provide the air 

needed for combustion indirectly, 

i.e. from adjacent rooms fitted with 

air circulation tubes as described 

above. However, these rooms must 

not be communal rooms, bedrooms 

or  rooms  that  may  present  a  fire 

hazard.

•  Liquid petroleum gas sinks to the floor as it is heavier 

than air. Therefore, rooms containing LPG cylinders must 

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

also be equipped with vents to allow gas to escape in 

the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored 

in rooms or storage areas that are below ground level 

(cellars, etc.). It is advisable to keep only the cylinder 

being used in the room, positioned so that it is not subject 

to heat produced by external sources (ovens, fireplaces, 

stoves, etc. ) which could raise the temperature of the 

cylinder above 50°C.

Fitting the appliance

Gas and mixed hobs are manufactured with type X degree 

protection against overheating. The following precautions 

must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than 

the top of the hob must be at least 600 mm from the edge 

of the hob.

•  Hoods must be installed according to their relative 

installation instruction manuals and at a minimum 

distance of 650 mm from the hob (see figure).

•  Place the wall cabinets adjacent to the hood at a minimum 

height of 420 mm from the hob (see figure).

If the hob is installed beneath a wall 

cabinet, the latter must be situated 

at a minimum of 700 mm above 

the hob.

Before the installation remove the grids and burners from 

the hob and turn it upside down, making sure you don’t 

damage the thermocouples and spark plugs.

Apply the seals that come with the appliance along the outer 

edges of the hob to prevent any passage of air, humidity 

and water (see Figure).

For proper application make sure the surfaces to be sealed 

are clean, dry and free of any grease/oil.

•  The installation cavity should have the dimensions 

indicated in the figure.

  Fastening hooks are provided, allowing you to fasten 

the hob to tops that are between 20 and 40 mm thick. 

To ensure the hob is securely fastened to the top, we 

recommend you use all the hooks provided.

600mm min.

420mm min.

650mm min.

Содержание G640N

Страница 1: ...ting Instructions HOB Contents Operating Instructions 1 Warnings 2 Assistance 2 Description of the appliance 3 Installation 4 Start up and use 8 Precautions and tips 8 Maintenance and care 9 Troublesh...

Страница 2: ...aintenance shall not be made by children without supervision WARNING Unattended cooking on a hob with fat or oil can be dangerous and may result in fire NEVER try to extinguish a fire with water but s...

Страница 3: ...RNERS 4 Ignition for GAS BURNERS 5 SAFETY DEVICES GAS BURNERS differ in size and power Use the diameter of the cookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS...

Страница 4: ...s it is heavier than air Therefore rooms containing LPG cylinders must A Examples of ventilation holes for comburant air Enlarging the ventilation slot between window and floor Adjacent Room Room to b...

Страница 5: ...ard plug suitable for the load indicated on the rating plate onto a cable and connect to a suitable socket To connect direct to the mains supply a double pole switch with a contact separation of at le...

Страница 6: ...d is not compressed Only use pipes and seals that comply with current national regulations Checking the tightness of the connection When the installation process is complete check the pipe fittings fo...

Страница 7: ...mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m3 At 15 C and 1013 25 mbar dry gas Propane P C S 50 37 MJ Kg Butane P C S 49 47 MJ Kg Natural P C S 37 78 MJ m3...

Страница 8: ...symbols appear in the manual and on the serial number plate The appliance was designed for domestic use inside the home and is not intended for commercial or industrial use The appliance must not be...

Страница 9: ...oved The burner caps should NOT be put in the dishwasher to prevent dulling of the aluminum part For hobs which ligth automatically the terminal part of the electronic instant lighting devices should...

Страница 10: ...10 GB PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24...

Страница 11: ...d and functioning efficiently throughout its life UK 08448 225 225 Republic of Ireland 0818 313 413 www hotpointservice co uk Appliance Registration We want to give you additional benefits of Hotpoint...

Страница 12: ...se neglect or interference or as a result of improper installation Replacement of any consumable item or accessory These included but not limited to plugs cables batteries light bulbs fluorescent tube...

Отзывы: