To avoid all risk, if the power cable becomes damaged, 
it  must  only  be  replaced  by  the  manufacturer, 
by  an  authorised  service  centre,  or  by  a  qualified 
electrician. 

Adaptation to various types of gas (Fig. 5)

Should the appliance be pre-set for a different type of 
gas than that available, proceed as follows:
•  replace the injectors (Fig. 5) with the corresponding 

type  of  gas  to  be  used  (see  table  “Uses 
characteristics”).

•  to adjust to the minimum, use a screwdriver on the 

screw placed on the tap (Fig. 6) after turning the tap 
to  its  minimum  position.  For  LPG  (butane/propane) 
screw tight

Fig. 6

wok C3 only

Fig. 5

USER CHARACTERISTICS

GAS BURNERS

feed

burner

ø injecTors TherMal capaciTy

Type

pressure mbar

noMinal

consuMpTion

norM.

1/100 mm

W

natural gas

G20    20

fast

129

3000

286

l/h

auxiliary

77

1000

95

wok 3

141

3500

333

liquefied gas

G30/G31    28-30/37

fast

87

3000

218

g/h

auxiliary

50

1000

73

wok 3

94

3500

254

Содержание G3201LIX

Страница 1: ... BY INCORRECT INSTALLATION OR BY UNSUITABLE WRONG OR ABSURD USE English GB Dear customer We thank you and con gratulate you on your choice This new carefully de signed product manu facturedwiththehighestqualitymaterials has been carefully tested to satisfy all your cooking demands We would therefore request you to read and follow these easy instructions which will allow you to obtain ex cellent re...

Страница 2: ...s burner is carried out by putting a smallflametotheupperpartholesoftheburner pressing and rotating thecorrespondingknobinananti klockwise manner until the maximum position has coincided with the marker When the gas burner has been turned on adjust the flame according to need The minimum position is found at the end of the anticlockwise rotation direction In models with automatic ignition operate ...

Страница 3: ... GB Fig 2 ...

Страница 4: ...lled equipment Installation This appliance is not provided with a combu stion product discharge It is recommended that it be installed in sufficiently aerated places in terms of the laws in force The quantity of air which is necessary for combu stion must not be below 2 0 m3 h for each kW of installed power See table of burner power Positioning Fig 2 The appliance can be fitted into a working area...

Страница 5: ...ding type of gas to be used see table Uses characteristics to adjust to the minimum use a screwdriver on the screw placed on the tap Fig 6 after turning the tap to its minimum position For LPG butane propane screw tight Fig 6 wok C3 only Fig 5 user characteristics gas burners feed burner ø injectors thermal capacity type pressure mbar nominal consumption Norm 1 100 mm W natural gas G20 20 fast 129...

Страница 6: ...em yourself 2 Switch the appliance on again to see if the problem has been solved if it has not disconnect the appliance from the power supply and wait for about an hour before switching on again 3 If the problem persists after this course of action contact After Sales Service Specify the nature of the fault the model the service number the number after the word SERVICE on the rating plate on the ...

Страница 7: ... Notes ...

Отзывы: