![Hotpoint DHG65G1CX Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/hotpoint/dhg65g1cx/dhg65g1cx_operating-instructions-manual_2167152006.webp)
6
GB
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
Table of burner and nozzle specifications
Table
1
Liquid
Gas
Natural
Gas
Burner Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By
Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm) (mm) *** ** (mm)
Tripple
Crown (TC)
130 3.25 1.50
63
2x65
236
232
2x99
309
Fast
(Large)(R)
100 3.00 0.7 41 86
218
214
116
286
Semi Fast
(Medium)(S)
75 1.90 0.4
30
70
138
136
106
181
Auxiliary
(Small)(A)
55 1.00 0.4
30
50
73
71
79 95
Oven
- 2.60 1.0
52
78
189 186 119 248
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
*
At 15 °C 10 13 mbar-d ry g as
***
Butane P.C.S. = 4 9,47 MJ/Kg
**
Prop ane P.C.S. = 5 0,37 MJ/Kg
Natural P.C.S. = 37,78 MJ/m³
DHG65G1CX
S
R
TC A
TECHNICAL DATA
Oven Dimensions HxWxD 31x43,5x43,5 cm
Volume 58
l
Useful measurements
relating to the oven
compartment
width 46 cm
depth 42 cm
height 8,5 cm
Voltage and frequency
see data plate
Burner s
may be adapted for use
with any type of gas
shown on the data plate
EC
Directives
2006/95/EC
dated 12/12/06 (Low
Voltage) and subsequent
amendments - 04/108/EC
dated 15/12/04
(Electromagnetic
Compatibility) and
subsequent amendments
- 2009/142/EC dated
30/11/09 (Gas)
1275/2008(Stand-by/Off-
mode)
ENERGY LABEL and
ECODESIGN
Regulation (EU) No
65/2014 supplementing
Directive 2010/30/EU.
Regulation (EU) No
66/2014 implementing
Directive 2009/125/EC.
Standard EN 15181\
Regulation (EU) No
66/2014 implementing
Directive 2009/125/EC.
Standard EN 30-2-1
ENERGY LABEL and
ECODESIGN
ENERGY LABEL and
ECODESIGN