background image

INSTALLATION - electrical requirements

9

Connection to the electricity supply should be made via a properly earthed, readily  accessible
wall socket which is adjacent to but not directly above, and not more than 1.25m away from the
appliance and capable of electrical isolation.
Should this plug not fit the socket outlet in your home it should be cut off and replaced with a
suitable plug as outlined below.

NOTE: The removed plug cannot be used for any other appliance and should therefore be
properly disposed of and not left where children might find it and plug it into a supply 
socket – with the obvious consequent danger.

IF THE FITTED PLUG IS REMOVED
The flexible mains lead must be correctly connected as below to a three pin plug of not less
than 13 amp capacity. If a B.S. 1363 fused plug is used, it must be fitted with a 3 amp fuse which
is approved to B.S. 1362.

IMPORTANT: The wires in the mains lead fitted to
this appliance are coloured in 
accordance with the following code:

GREEN AND YELLOW –  EARTH
BLUE 

–  NEUTRAL

BROWN

–  LIVE

As the colours of the wires in the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:– The wire which is
coloured green and yellow must be connected to the terminal in the plug which is marked with
the letter E or by the earth symbol          or coloured green or green and yellow. The wire which is
coloured blue must be connected to the terminal which is marked with the N or coloured black.
The wire which is coloured brown must be connected to the 
terminal which is marked with the letter L or coloured red. When wiring the plug, ensure that all
strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead
clamp on the plug. As the appliance must be earthed, do not use 2-pin 
sockets outlets, if you are in doubt, consult a qualified electrician.

Should the mains lead ever require replacement, it is essential that this operation be 
carried out by a qualified electrician and should only be replaced with a flexible cord of the
same size i.e. 0.75mm

2

cross sectional area and temperature rating of 85

C e.g. heat resisting

PVC. 

IF A MOULDED PLUG IS FITTED
In the event of replacing a fuse in the plug supplied a 3 amp ASTA approved fuse to BS1362
must be fitted.
NOTE: The fuse cover must be refitted when changing the fuse. In the event of losing the
fuse cover the plug must not be used until a replacement fuse cover has been obtained and
fitted. A new fuse cover can be obtained from your local Electricity Board. The colour of the
correct replacement fuse cover is that of the coloured marks or inserts in the base of the plug.

Make sure that the cable does not become trapped.

WARNING –

THIS APPLIANCE MUST BE EARTHED.
CONNECT TO A 230-240V A.C. SUPPLY ONLY.

Green &
Yellow to
Earth

Brown to
Live

Blue to
Neutral

Cord Clamp

3 Amp
Fuse

FP087-01 HP Gas Hob (BG05)  12/09/2001  4:59 pm  Page 9

Содержание BG05

Страница 1: ...e found on the rating plate To the User You must read the instructions prior to using the appliance and then retain them for future reference This appliance must be installed in accordance with regula...

Страница 2: ...t be kept handy for reference as it contains important details on the safe and proper use of the appliance If you sell or pass the appliance to someone else or move house and leave it behind make sure...

Страница 3: ...responsibility will not be accepted for use in any other installation The guarantee is subject to the provisions that the appliance a Has been used solely in accordance with the Users Instruction Boo...

Страница 4: ...efore frying and lower it slowly into the hot oil or fat Frozen foods in particular will cause frothing and spitting if added too quickly Always keep the outside of the pan clean and free from streaks...

Страница 5: ...n the hob surface Never fill a deep fat frying pan more than 1 3 full of oil or use a lid DO NOT LEAVE UNATTENDED WHILE COOKING Never use the appliance as a room heater Never dry any items on the hob...

Страница 6: ...EN USING THE GAS HOB Step 1 Check that the electricity is switched ON Step 2 Press the ignition button and then push and turn the control knob of the chosen burner anticlockwise to the large flame sym...

Страница 7: ...lon brush to remove any cleaning materials water or dirt from the burner bodies Re assemble as in the diagram below Wipe over the knobs with a soft cloth wrung out in hot soapy water or mild non abra...

Страница 8: ...left in a condition where it could be connected to the electricity supply To help the environment Local Authority instructions should be followed for the disposal of you product Disposal of your produ...

Страница 9: ...reen or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the N or coloured black The wire which is coloured brown must be connected to the termin...

Страница 10: ...se models are set to burn NATURAL GAS G20 at 20mbar They can also be converted to burn BUTANE GAS G30 at 28mbar or PROPANE GAS G31 at 37mbar using the conversion kit included Gas Category II2H3 GB IE...

Страница 11: ...e UK CORGI registered installers work to safe standards of practice The cooker must also be installed in accordance with BS 6172 Failure to install the cooker correctly could invalidate the warranty l...

Страница 12: ...to avoid the possibility of disturbing gas tight joints inside the hob Ensure that the inlet is held securely When loosening or tightening the hob gas pipe securing nut When connecting fittings to it...

Страница 13: ...pth 50mm Worktop thickness Preferred 30 40mm 19mm minimum recommended 30mm 489mm 558mm Front edge of worktop Note Do not over tighten the hob clamps as distortion of the hob may occur Fig 2 FIXING CLA...

Страница 14: ...emove pan supports burner caps burner bodies and control knobs Fig 2 2 Remove each injector and replace with LPG injector using 7mm A F hexagonal socket Fig 3 3 Turn each gas tap bypass screw fully cl...

Страница 15: ...Service Organisation located throughout the United Kingdom and Eire We will be happy to deal with any problems which you may have Hotpoint s Extended Warranties Whether you have just one or a number...

Страница 16: ...ar and concise details of the query or fault Place and Date of purchase Please keep the receipt as evidence will be required when the engineer calls Extended Warranty To join UK 08709 088 088 Republic...

Отзывы: