Service Manual UK
Indesit
Company
English
F06
Door lock fails to
close / open, door
lock PTC triac
open / closed,
mains frequency
signal fault,
mains power
signal fault
- Check for water leaks that may affect connectors
J004
or
J11
(three-
phase) causing the relative contacts to short;
- Check Door lock terminal board (any problems due to aggression
caused by manufacturing chemical residues that may cause short
circuits);
- Check
J004
/ door lock wiring;
- Check door lock;
- Renew PCB.
F07
Wash heating
element relay
open / diverter
relay sticking on
drain pump side
- Check efficiency of contacts on connector
J001
(commutator) or
J10
(three-phase) on PCB;
-
Check
continuity of wash heating element on connectors
J001 (Commutator)
or
J10
(Three-phase), pins 3 and 4. The
1700W
230V
heating element impedance value is 30
Ohm +/-
10%. If value is
different renew wash heating element;
- Renew PCB.
F08
Wash heating
element relay
earth leak- age /
wash heating
element relay
contacts sticking
- Check efficiency of contacts on connector
J001
(commutator) or
J10
(three-phase) on PCB;
- Check leakage between the two ends and ground, impedance should
be at least 2 MOhm;
- Renew heating element;
- Renew PCB.
F09
Setting File error
detected by Main
PCB or Display
PCB
- Disconnect appliance for 2 minutes. Check that correct operation has
been restored by starting the Autotest routine;
- Reprogram Main PCB;
- Renew main PCB;
- Renew display PCB.
F11
Pump not wired
or pump driving
triac short circuit
- Check efficiency of contacts on connector
J004
(commutator) or
J11
(three-phase) on PCB;
- Check continuity on connector
J004
(commutator) or
J11
(three-
phase), pins 4 and 5 (in the case of classic door lock);
- Check continuity of pump, ensuring that impedance value is 170
Ohm +/- 10%;
- Check wiring of connector
J004
(commutator) or
J11
(three phase) /
pump;
- Renew pump;
- Renew PCB.
F12
Communication
error between
Main PCB and
Display PCB
- Check efficiency of contacts on connector
J010
(Commutator) or
J16
(Three-phase) on main PCB;
- Check efficiency of contacts on Display PCB;
- Check continuity of
J010
(Commutator) or
J16
(Three-phase)/
Display PCB wiring;
- Disconnect appliance, wait for 2 minutes and reconnect to power
supply, then start autotest routine;
If problem persists proceed as follows:
- Renew main PCB;
- Renew display PCB.