3
GB
Condenser unit
- You
must
clean the fluff from
the condenser
every
month!
Step 1
Open the Condenser Cover
- hold the handle and pull
towards you.
Step 2
Remove the condenser by
rotating the 3 clips then pulling
the condenser towards you.
(There may be some water in the
tubes this is normal).
Step 3
Flush the condenser, from the
rear with water, to remove any
fluff deposits.
Step 4
Refit the condenser unit - ensure
that the unit is pushed in fully, all
3 clips are resecured and the
positioning arrows on the front of
the condenser are pointing
upwards.
Failure to clean the condenser could cause
premature failure of your dryer!