18
GB
Service
Heat Pump System
This dryer is fitted with a sealed heat pump system to dry
your clothes. To operate, the heat pump contains fluorinated
greenhouse gases ( F gases) which are covered by the Kyoto
Protocol. These F gases are contained in a hermetically
sealed unit. This sealed unit contains 0.34 kg of the F gas
R134a which acts as a refrigerant.
If the sealed unit fails then it must be replaced by a new
sealed unit. Contact your nearest service centre for advise.
Note:
The gases contained in the sealed unit are not
hazardous to health, but if they escape they will have an
impact on global warming.
Before calling the Service Centre:
• Use the troubleshooting guide to see if you can solve
the problem yourself
(see Troubleshooting).
• If not, turn off the dryer and call the Service Centre
closest to you.
What to tell the Service Centre:
• Name, address, and post code;
• telephone number;
• the type of problem;
• the date of purchase;
• the appliance model (Mod.);
• the dryer serial number (S/N).
This information can be found on the data label inside the
door of the machine.
Spare Parts
This dryer is a complex machine. Repairing it yourself or having
a nonauthorised person try to repair it could cause harm to one
or more persons and to the machine, and could invalidate the
spare parts warranty.
Call an authorised technician if you experience problems while
using the machine.
Please note that it is an offence for an unqualified person to
undertaken any servicing or repair work that involves breaking
into the sealed heat pump unit.
The spare parts have been designed exclusively for this
appliance, and not for other uses.
Comparative Programmes
• Programmes recommended for comparative test to EN61121.
Programme (EN61121)
Programme to select
Load size
Sensor Dry Option
Dry cotton
Cottons High Heat
8 kg
Cupboard
Iron dry cotton
Cottons High Heat
8 kg
Iron
Easy-care textile
Synthetics
3 kg
Cupboard
!
Note: This in not a full list of programme options
(see Start and Programmes).
This appliance conforms to the following EC Directives:
- 2006/95/EC (Low Voltage Equipment);