Burner and nozzle specifications
Table 1 Liquid Gas Naturale Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Fast (R)
Reduced Fast (RR)
Ultra Rapid (UR)
Semi Fast (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
100
100
75
55
110
3.00
2.60
3.40
1.65
1.00
3.50
Nomin.
Reduc.
0.70
0.70
0.70
0.40
0.40
1.50
By-pass
1/100 (mm)
41
41
41
30
30
—
(1)
39
39
39
28
28
61
Nozzle
1/100
Flow*
g/h
(mm)
***
86
80
91
64
50
91
Nozzle
1/100
Flow*
l/h
(mm)
116
110
123
96
79
138
286
248
324
157
95
333
218
189
247
120
73
254
**
214
186
243
118
71
250
*
At 15°C and 1013 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
(1) Only for appliances with the security device.
Ø 145
S
R
S
A
S
R
S
A
S
RR
MW
A
UR
RR
S
S
A
MW
RR
S
S
TD 750 S IX/HA
TD 751 S GH/HA
TQ 751 S GH/HA
TQ 751 S IX/HA
TZ 751 S /HA
TD 751 S IX/HA
TZ 751 S N/HA
TZ 751 S K/HA
TQ 751K X/HA
TQ 751K GH/HA
TD 640 IX/HA
TD 640 S GH/HA
TD 640 S IX/HA
TQ 640 S GH/HA
TQ 640 S IX/HA
TZ 640 S /HA
TQ 640K GH/HA
TQ 640K X/HA
A
S
R
S
TD 740 S IX/HA
TD 641 S IX/HA
TD 631 S IX/HA