value.At  last  press“

”or  no  any  operation 

for 5seconds to exit setting.

 

Timing Turn 

on/off Setting

 

In turn on state,long press“

”for 3-5 

seconds to enter into setting screen, choose 

”icon,press“

”confirm to timing turn 

on setting,it displays “ON”and “--;--”or “hh 

mm”flashing at the same time,press press 

” to confirm and press “

”or“

”to 

adjust the hour and press “

” and 

”or“

” to adjust minute of turn 

on,adjust to “--;--” and press “

” to cancel 

timing turn on and enter into timing turn off 

setting,it displays“OFF ”and “--;--”or “hh 

mm”flashing at the same time,press press 

” to confirm and press “

”or“

”to 

adjust the hour and press “

” and 

”or“

” to adjust minute of turn 

off.Cancel timing turn on/off setting:just to 

adjust Aoth timing turn on and turn off 

as“--”;(timing turn on/off for one time or 

cycle running,please set it in advanced 

setting) 

 

 

 

Working Mode 

Choice

 

In  turn  on  state,long  press“

”for 

3-5seconds 

to 

enter 

into 

setting 

screen,choose  “

”  and  press  “

”to 

confirm:switch  working  mode  Aetween   

”.Display“

”  means 

cooling  mode,display“

”means  heating 

mode,display“

  ”means 

ventilation 

mode(HTW-IZ19-1-2P 

no 

heating 

mode);display  “

”means  cooling,heating 

mode 

switch 

automatically(HTW-IZ19-1-4P-A).

 

 

Auto heating mode Auto cooling mode 

 

  heating mode          cooling mode

 

Manual And 

ProgrammaAle 

Mode Choice

 

In turn on state,short press“

”for one time 

to run programmaAle mode;press “

” 

again to run manual mode 

HTW-IZ19-1-4P-M(MODBUS  and  RS485 

version no programmaAle function)

 

 

Motorized 

Valve Control

 

In  the  cooling  (heating)  mode,  when  the 

room  temperature  is  equal  to  the  set 

temperature,  the  valve  outputs  the  control 

voltage  5V,  for  example,  the  valve  output 

control  voltage  is  set  to  10  aliquots  "Refer 

to the advanced option P",   

1:  In  the  cooling  mode,when  room 

temperature lower than set temperature of 1

,then  output  4V;  when  room  temperature 

low than set temperature of 2

,then output 

3V;when  room  temperature  higher  than  set 

temperature of 1

,then output 6V 

2:In 

the 

heating 

mode,when 

room 

temperature  highter  than  set  temperature  of 

1

,then output 4V; when room temperature 

highter  than  set  temperature  of  2

,then 

output  3V;when  room  temperature  lower 

than set temperature of 1

,then output 6V 

Ventilation mode (fan is not 

controlled) 

Fan control, the valve output 

control is lower than the 

voltage 5V fan is turned off

 

Key Lock 

Function

 

Key  Lock  function:if  thermostat  opens  key 

lock  function,no  any  operation  after  10 

minutes will lock keys automatically(screen 

display  “ 

  icon),press    “

”  for  5 

seconds will unlock(“ 

 disappears)

 

 

Door Key 

Energy Saving 

Mode(HTW-IZ

19-1-K) 

 

Enter into energy saving mode Ay door 

card.When pull out door card, “

”door 

card icon flashing,if thermostat is in cooling 

mode,temperature set as    26

 

automatically,fan run in low speed;if 

thermostat is in heating mode,temperature 

 

Отзывы: