background image

Wifi Wireless Thermostatic Radiator Valve Actuator 

HTW-31RT 

 

 

 

 

3)  Turn   HTW-31RT  off  by  pressing  ON/OFF  button, then  long press  

M  

button  until  it  show a “0  and  

signal  icon”, then press 

UP 

button, when HTW-31RT display 

or  

signal  icon  stop moving

means code pairing done. Press ON/OFF button to return, and press again to turn it on. 

 

  

Parameter setting  

Turn off the thermostat, Press and hold 

and 

UP 

button for 3s, until it shows the item 01, each press of 

button will go 

to next item setting, adjust the range by using 

UP 

and 

DOWN 

button. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

Mounting   

 

 

Menu 

Description 

Range 

Default Value 

01 

Temp. calibration for internal sensor 

-8 

 ~8 

 

0

 

02 

Set Point Max. 

 

~35

 

35 

 

03 

Set Point Min. 

 

~35

 

 

05 

Frost Protection Temp. 

 

~15

 

 

10 

Display 

0: Room temp. 

1: SET temp. 

12 

Open window detect function 

1: ON  0: OFF 

13 

OWD Detect Time 

2~30mins 

15mins 

14 

OWD Drop temp. select 

within detect time

 

2.3.4’C 

2 ‘C 

15 

OWD Delay time select 

(Return to previous working status) 

10~60min 

30mins 

17 

Factory reset 

0: No 

1: Yes, and then press 

On/off button for 5s,wait 

until thermostat restart 

18 

Software version 

 

 

19 

Software version 

 

 

31 

Battery voltage 

Unit: 10mv 

 

32 

PID  P-band select 

 

~10

 

7

 

33 

PID  I-time select 

30~90min 

30min 

 

Отзывы: