24
TH-260D1 All in One Heat Pump Manual
The TH-260D1 is positioned on a level surface.
A minimum of 300 mm distance is available above the TH-260D1 to allow re-
moval of the lid for maintenance (see section 3.4 Air Flow).
A minimum of 600 mm distance on the fan discharge side and 250 mm mini-
mum on the air intake side of the TH-260D1 is provided for air flow (see sec-
tion 3.4 Air Flow).
A minimum of 150 mm is provided between the exterior of the tank and any
obstructions/walls to provide space for air circulation and servicing (see section
3.4 Air Flow).
The condensate drainage elbow is hand tight (see section 4.1 TH-260D1 Con-
nection Dimensions and Components).
The drain from the condensate drainage elbow is free flowing and is not con-
nected directly to any other pipeline or the TPR valve (see section 4.1 TH-
260D1 Connection Dimensions and Components).
The purpose of the tempering valve has been explained to the customer
Valves are fitted on the water inlet and outlet to the unit.
Unit is set to 60°C
The TH
-
260D1 is installed on a stable structure which can hold more
than 400kg
CHECKLIST
Once the system is installed, the installer must sign below to ensure compliance with
all procedures, otherwise the warranty may be void.
Installer Full Name:
Date:
Signature of Installer:
Once you have carried out all these checks you are ready to switch on the unit