Hot Shot 810-R Plus Скачать руководство пользователя страница 1

  

 

IRRIGATION 

810-R PLUS 

RECEIVER GUIDE 

Pg.   

HOT SHOT OVERVIEW 

RECEIVER INDICATOR LEDS 

FUNCTION SWITCH SETTINGS 

SUPERVISION FEATURE 

SUPERVISION FAIL SAFE FEATURE 

ENGINE STARTUP  MODE 

LOAD SHARING FEATURE 

MULTIPLE RELAY OUTPUT CONTROL 

RECEIVER HOOKUP TO ELECTRIC WELL 

RECEIVER HOOKUP TO ELECTRIC WELL DIAGRAM 

RECEIVER HOOKUP TO ENGINE DRIVEN WELL 

Version : 1006 

Hot Shot Systems Inc. will no longer sell or warranty its products for the use in controlling or monitoring pollut-
ants.  However, the use of these controllers in non pollutant applications such as water tanks, water pumps, pivots, 
irrigation systems and any other monitoring or control applications that do not involve pollutants are suitable for 
these products. 

Содержание 810-R Plus

Страница 1: ... ELECTRIC WELL 7 RECEIVER HOOKUP TO ELECTRIC WELL DIAGRAM 8 RECEIVER HOOKUP TO ENGINE DRIVEN WELL Version 1006 Hot Shot Systems Inc will no longer sell or warranty its products for the use in controlling or monitoring pollut ants However the use of these controllers in non pollutant applications such as water tanks water pumps pivots irrigation systems and any other monitoring or control applicati...

Страница 2: ...modifications not expressly approved by the party re sponsible for compliance could void the user s authority to operate the equipment HOW IT WORKS Think of the HOT SHOT system as a control wire going from the transmitter site to the receiver site When the Hot Shot Transmitter s SENSOR ON OFF Input is connected to COM a 10 second delay timer is started After the delay timer has expired the transmi...

Страница 3: ...KEY to the left to make each digit of the code It takes three of the switches to make one num ber of the code Use switches 1 2 3 for the first in the code Switches 4 5 6 for the second Switches 7 8 9 for the third Switches 10 11 12 for the fourth Transmitter Code Switches INDICATOR LEDS POWER Signals that the Receiver has power and is ready to receive the code from the Transmitter STROBE Used for ...

Страница 4: ... the internal supervision timer expires due to transmitter or receiver issues the receiver will then look at its function switches 7 8 or 9 and take the selected course of supervision action See below FAIL SAFE OPERATION RELAY 1 OUTPUT ONLY This feature works with the Supervision feature as described above but lets us take safety a step further Fail Safe mode allows the receiver to control the 1 i...

Страница 5: ...d with a Hot Shot 810 T transmitter using it s 1 2 3 4 5 OR 6 SENSOR INPUT or the Pump Selector Kit the receiver s going to be used will need to use the corresponding transmitter SENSOR INPUT termi nals to control the pump or relay outputs accordingly The 1 Sen sor Input on the transmitter will only turn ON and OFF the 1 Relay Terminals on the receiver The same goes for the 2 Sensor Input on the t...

Страница 6: ...ire the 120v X2 terminal of the step down transformer to the neutral 120vac input of the Hot Shot Receiver see diagram on the next page Add a jumper from the first 120vac terminal to the Hot Shot Receivers relay COM terminal see diagram on the next page Wire the NO terminal on the Hot Shot Receiver to one side of the 120v relay coil Connect the other side of the relay coil to the X2 terminal of th...

Страница 7: ... ON SIGNAL IT WILL CLOSE ITS N O TO COMMON CONTACTS THIS WILL ENERGIZE THE 120V RELAY TO CLOSE THE 480V CONTACTOR ELECTRIC WELL HOOKUP DIAGRAM W 3 RELAYS IN PARALLEL This diagram illustrates how to let an electric pump stay operating until all the transmitters have sent their turn off command It is a sim ple way of wiring all the receiver relays in parallel so that the pump stays operating until a...

Страница 8: ...nnect a wire from the N C terminal on the Hot Shot receiver to the S or the SW1 terminal on the Murphy kill switch Turn on function switch 6 and turn on the power to the receiver to enable the Engine Startup Mode for details see pg 4 When activated the Supervision LED will come on and bypass the Murphy switch to allow the engine to start and stay running until the transmitter has sent its relay ON...

Страница 9: ...ot has various lightning and static protection devices incorporated on the cir cuit board that require proper grounding to operate Any equipment or device panels operating with or near the Hot Shot should also be con nected to the grounding system A good ground will enhance the trans mit and receive range of the Hot Shot System GROUNDING PER NATIONAL ELECTRICAL CODE DEVICE PANEL ...

Страница 10: ...g or losing power to the receiver Operational Note When using Fail Safe Scenario 1 the receiver s relay is energized and if power is lost while the receiver is in Fail Safe operation the receiver s relay will de energize When power is restored the re ceivers relay will not immediately go back into Fail Safe operation The receivers relay will remain de energized and the device it is controlling may...

Отзывы: