0
c) Pump-Out Timer (S4 dip switch 3 & 4)
During cycles when a pump out is called for, the pump motor drains the water tank for
the time determined by the pump-out timer (T1). The pump-out timer's harvest timer (T)
acts in place of the harvest timer (S4 dip switch 1 & ) during cycles with a pump out.
The pump-out timer is factory-adjusted, and no adjustment is required.
Dip Switch Setting
Time (seconds)
Harvest Water
Valve
No. 3
No. 4
T1
T
OFF
OFF
10
150
Closed
ON
OFF
10
180
Closed
OFF
ON
10
10
Open
ON
ON
0
180
Closed
T1: Time to drain the water tank
T: Harvest timer at pump out
Depending on the pump-out frequency control setting (dip switch 5 & 6), pump out
occurs every cycle, or every nd, 5th or 10th cycle.
d) Pump-Out Frequency Control (S4 dip switch 5 & 6)
The pump motor drains the water tank at the frequency set by the pump-out frequency
control.
The pump-out frequency control is factory-adjusted to drain the water tank every 10
cycles, and no adjustment is required. However, where water quality is bad and the
icemaker needs a pump out more often, the pump-out frequency can be adjusted as
shown in the table below.
Dip Switch Setting
Frequency
No. 5
No. 6
OFF
OFF
every cycle
ON
OFF
every cycles
OFF
ON
every 5 cycles
ON
ON
every 10 cycles
e) Factory Use (S4 Dip Switch 7 & 8)
Factory set for optimum performance. Do not adjust.