28
765042226 Rev.000
DISCONTINUED USE
Should the machine be disconnected over long periods, follow the instructions below
to maintain the appliance in good condition:
Turn the mains switch OFF.
Disconnect the plug.
Empty the appliance and clean it in accordance
with the instructions given in the chapter
"CLEANING".
Leave the door ajar to prevent a
bad smell.
Cover the compressor unit with a nylon cloth to
protect it from dust.
In case of appliances with remote control, if you
decide to turn it off, remember to put the switch
off also in the remote control..
ENERGY CONSUMPTION CHART
Energy Consumption Chart
SBU 15 H SBU 20 HL SBU 20 HT SBU 40 HT
Chilled full load capacity [kg]
15
20
20
42
Cooling temperature [°C]
+65 ‐ +10
Time cycle ( chilling ) [min]
120
Energy consumption for chilling
[kWh/kg]
0,124
0,089
0,089
0,137
Frozen full load capacity [kg]
8
12
12
25
Freezing temperature [°C]
+65 ‐ ‐18
Time cycle ( freezing ) [min]
270
Energy consumption for freezing
[kWh/kg]
0,492
0,313
0,313
0,413
Refrigerant name
R404A
GWP
3922
Refrigerant charge [kg]
0,48
1,4
1,4
2,0
OFF