28
Cleaning
4) Remove the top, left side, and insulation panels, then disconnect the distributor from the
distribution hose. Remove the thumbscrew securing cube guide B, then remove cube
guide B and cube guide A. See Fig. 14.
5) Remove the overflow cap, overflow pipe, and drain plug. After the water tank has
drained, replace the drain plug, overflow pipe, overflow cap, cube guide A, cube
guide B, and reconnect the distributor to the distribution hose, then replace the
insulation, left side, and top panels.
NOTICE!
Be careful not to cross thread the drain plug or overflow pipe.
6) To fill the water tank, move the control switch to the "ICE" position, then replace the front
panel. After 3 min., remove the front panel, then move the control switch to the "OFF"
position.
7) Remove the top, left side, and insulation panels, then pour 14 fl. oz. (414 ml) of
Hoshizaki "Scale Away" into the water tank. Replace the insulation, left side, and top
panels. Turn the cleaning valve to the left until completely vertical (open).
8)
NOTICE!
To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
9) After 30 min., remove the front panel, then move the control switch to the "OFF"
position.
10) Remove the top, left side, and insulation panels, then disconnect the distributor from the
distribution hose. Remove the thumbscrew securing cube guide B, then remove cube
guide B and cube guide A.
Fig. 14
Cube Guide A
Distribution
Hose
Cube Guide B
Thumbscrew
Drain Plug
Overflow Cap
Overflow Pipe
Insulation Panel
Front Panel
Ice
Storage
Bin
Top Panel
Cleaning
Valve
Left Side Panel
Distributor