6
The attachment plug blades, their
vicinity, and receptacle are dusty.
Clean.
The attachment plug is plugged into a
single receptacle with other equipment.
Plug into a separate
receptacle.
The unit shares a single power supply
with other equipment.
Use a separate power supply.
[i] CONSUMABLE/PERIODIC REPLACEMENT PARTS
Consumable parts:
pH test paper UNIV
Chlorine test paper
Water hardness indicator
Neutralizing agent
Periodic replacement parts:
Electrolytic cell (3000 hours)
10. PREPARING ELECTROLYZER FOR LONG STORAGE
WARNING
When shutting down the electrolyzer for more than a week, turn
off the power switch (earth leakage circuit breaker), and unplug
the unit to prevent electric leak, heat generation, or ignition.
IMPORTANT
Before operating the water electrolyzer next time, check that
the drain valve is closed and open the water supply line shut-off
valve.
1) Follow the “6. SHUT DOWN” and shut down the unit.
2) Close the water supply line shut-off valve.
3) Drain salt water from the salt water tank and rinse the inside the
salt water tank to remove salt completely with tap water.
4) Fill the salt water tank with tap water and connect the salt water
hose.
5) Follow the “4. PURGING SALT WATER PUMP” to wash the salt
water circuit with tap water. Keep the water running for at least 30
seconds.
6) Disconnect the salt water hose from the salt water tank and drain
the hose. Wipe out the salt water hose and salt water filter with a
clean cloth.
7) Drain the water from the salt water tank.
8) Turn the power switch (earth leakage circuit breaker) off and close
the door.
9) Open the drain valve on the back of the unit or remove the drain
cap to drain the remaining water.
10) Open the water supply line drain valve.
11. BEFORE CALLING A SERVICE AGENT
If something seems wrong with the unit, check for possible causes
according to the following instructions.
If the problem still exists, turn off the power switch (earth leakage
circuit breaker), unplug the unit, and contact an authorized Hoshizaki
service company.
Only qualified personnel may repair the unit. Do not attempt to repair
it yourself.
[e] CELL RUN TIME, CURRENT, VOLTAGE (AS REQUIRED)
To check the cell run time, current, and voltage:
1) Open the control panel door.
2) Turn on the power switch (
earth leakage circuit breaker).
3) Press the display select button on the control panel.
4) Press the display select button until the desired item appears in the
display.
Note: It is factory adjusted to display the cell run time first.
5) Close the door.
[f] WATER HARDNESS (WEEKLY)
IMPORTANT
Continuous use with hard water may cause clogged pipes,
reduction in performance, or failure of the electrolytic cell. If
sampled water is hard, contact an authorized Hoshizaki service
company.
1) Open the water sampling tap. Let water run for more than 5
seconds. Sample water in the measuring cup.
2) Pour one or two drops of the water hardness indicator into the
measuring cup, and stir a little. Check the water hardness (red =
hard water, blue = soft water).
Note: For details, follow the instructions of the water hardness
indicator.
[g] EARTH LEAKAGE CIRCUIT BREAKER (MONTHLY)
WARNING
Check the earth leakage circuit breaker for proper operation
once a month. If it is left inoperable, it could increase the risk of
electric shock in case of electric leak.
1) Press the test button of the power switch
(earth leakage circuit breaker).
2) Check that the switch turns off. If not,
immediately contact an authorized Hoshizaki
service company.
[h] POWER CORD, EARTH WIRE, ATTACHMENT PLUG
(ANNUALLY/BIANNUALLY)
WARNING
Check periodically that the attachment plug blades and their
vicinity are free of dust and that the attachment plug is securely
plugged into the receptacle. Dusty blades or loose connection
may cause electric shock or fire.
* If the supply cord and/or the plug should need to be replaced, it
should only be done by a qualified service engineer.
* Check for the following problems:
Problem
Remedy
The earth wire is broken or loosely
connected.
Ask an authorized Hoshizaki
service company or licensed
electrician for repair.
The attachment plug or power cord is
too hot, damaged, weighed down, or
caught in.
Immediately ask an
authorized Hoshizaki service
company for repair.
OFF
Test button