31
B. Important Notes for Component Replacement
NOTICE
• When replacing a component listed below, see the notes to help ensure proper
operation.
Component
Notes
Compressor
Install a new start relay, start capacitor, and external protector (on 2-section freezers only).
Compressor,
Evaporator
Fan Motor,
Condenser Fan
Motor
WARNING! To reduce the risk of electric shock, be sure to reconnect the
component's ground wire.
Thermostatic
Expansion Valve
• Attach the thermostatic expansion valve bulb to the suction line in the same location as
the previous bulb.
• Secure the bulb with the clamp and holder, then insulate it.
Defrost
Thermistor
After working with or around the defrost thermistor on a freezer, make sure the defrost
thermistor wire is not touching the defrost heater.
C. Door Reversal
The appliance is provided with a cabinet design which, after being delivered to the
installation location, permits changing of the door swing from left to right or right to left.
To change the door swing, an HS kit from your local Hoshizaki distributor is required. See
the table below.
NOTICE!
Improper installation of the HS kit may result in the doors
not closing completely and/or the gaskets not sealing correctly
. For further details,
contact your local Hoshizaki distributor or Hoshizaki Technical Support at
1-800-233-1940.
Door Type
Convert
HS Kit Number
Full Glass
Right Hinge to Left Hinge
HS-5177
Left Hinge to Right Hinge
HS-5176
Full Solid
Right Hinge to Left Hinge
HS-3726
Left Hinge to Right Hinge
HS-3725
Half Solid
Right Hinge to Left Hinge
HS-3725
Left Hinge to Right Hinge
HS-3726