29
2. Bin Control 2 (mechanical backup) Check
When the actuator paddle is not engaged BC2 is closed and the icemaker produces ice.
a) Bin Control 2 (mechanical backup)
: With S1 dip switch 7 placed in the "ON"
position, BC2 is used as a backup bin control safety. When ice fills the chute and
engages the actuator paddle, BC2 opens and CB immediately shuts down the
icemaker and sounds a 9-beep alarm.
b) Bin Control (mechanical stand-alone)
: With S1 dip switch 7 placed in the "OFF"
position, BC is used as a stand-alone bin control. The stand-alone application should
only be used in Hoshizaki standard ice storage bin applications.
WARNING! Do not
place S1 dip switch 7 in the "OFF" position on dispenser unit applications.
This could lead to icemaker movement or ice overflow.
When ice fills the chute
and engages the actuator paddle, BC opens and CB shuts down the icemaker within
10 sec.
1) Remove the front and top panels.
2) Move the power switch to the "OFF" position, then unplug the appliance from the
electrical outlet.
3) Remove the strap connecting the spout to the chute assembly. See Fig. 4. Pull up the
chute assembly slightly so that you can access the actuator paddle located in the top of
the chute.
4) Plug the appliance into the electrical outlet.
5) Move the power switch to the "ON" position to start the automatic icemaking process.
6) Make sure CB "GM" LED is on. There is a delay of at least 30 sec. before CB "GM" LED
turns on after power-up. After CB "GM" LED turns on, press CB "SERVICE" button to
bypass the 5-min. ice purge cycle.
WARNING! Risk of electric shock. Care should be
taken not to touch live terminals.
CB "COMP" LED turns on.
Fig. 4
Chute Assembly
Actuator
Spout
Strap
BC2 (mechanical backup) (proximity switch)
Strap
Model Shown: FS-1500MLH-C