20
* Use the Adjust Bolts at the bottom to level
the unit.
* To attach the accessory Adjustable Legs
(100mm long), replace the Adjust Bolts at
the bottom with the four Adjustable Legs
provided, and adjust them to level the unit.
Adjust Bolt
Longer Shorter
Max 1 cm
3. ELECTRICAL CONNECTIONS
WARNING
1. The connections must be made to a separate power supply or receptacle in
accordance with the national and local electrical code requirements and this
Instruction Manual. Improper connections may cause electric shock or fire.
2. Disconnect the main power supply before making any electrical connections
to prevent possible electric shock. Attach a sign to warn against turning on
the power supply during the electrical work.
CAUTION
The maximum allowable voltage variation should not exceed ±10 percent of the
rated voltage. Operation of the unit outside of this range may cause smoking,
ignition, damage to the unit or reduction of the performance.
* The main power supply (circuit breaker) and
receptacle must have a capacity of not less than 2.8A
(IM-30M, LM-250M), 3.2A (IM-45M), 3.4A (IM-65M) or
3.8A (LM-350M).
Switchboard
Main Power Supply
(Circuit Breaker)
Receptacle
Attachment Plug