Part No 68000132
No 091-2 7 April 2020
STEP 3
– Reconnection of equipment
Reconnect and neatly lay the electrical leads back
into the electrical control box.
TIP -Reference the chiller manual electrical
drawing and previously taken photos will assist.
3.1
Power Lead
•
Brown lead to terminal A.
•
Blue lead to the neutral terminal J2.
•
Earth lead to the earth screw with main earth
from control board.
IMPORTANT: Ensure that the supply cable is fixed to the electrical box base with the P-Clip.
3.2
Carbonator pump
•
Brown lead to terminal J5.
•
Blue lead to the neutral terminal J16.
•
Earth lead to the earth terminal J12.
3.3
Soda recirculation pump
•
Brown lead to terminal J7.
•
Blue lead to the neutral terminal J18.
•
Earth lead to the earth terminal J13
Terminal A
Terminal J2
P-Clip
Earth screw
POWER CABLE
J5
J16
J12
CARBONATOR PUMP
J7
J18
J13
SODA PUMP
INSTRUCTIONS FOR S4E V3 AGITATOR
REPLACEMENT WITH IEC HARNESS