Hoshizaki KMD-860MAJ Скачать руководство пользователя страница 4

4

Important Safety Information

Throughout this manual, notices appear to bring your attention to situations which could 
result in death, serious injury, damage to the appliance, or damage to property. 

 WARNING  

Indicates a hazardous situation which could result in death or 
serious injury. 

NOTICE 

Indicates a situation which could result in damage to the 
appliance or property.

IMPORTANT 

Indicates important information about the installation, use, and 
care of the appliance.

 WARNING

The appliance should be destined only to the use for which it has been expressly 
conceived. Any other use should be considered improper and therefore dangerous. 
The manufacturer cannot be held responsible for injury or damage resulting 
from improper, incorrect, and unreasonable use. Failure to install, operate, and 
maintain the appliance in accordance with this manual will adversely affect safety, 
performance, component life, and warranty coverage and may result in costly water 
damage.
To reduce the risk of death, electric shock, serious injury, or fire, follow basic 
precautions including the following:
• Only qualified service technicians should install and service the appliance.
• The appliance must be installed in accordance with applicable national, state, and 

local codes and regulations.

• Electrical connection must be hard-wired and must meet national, state, and local 

electrical code requirements. Failure to meet these code requirements could result 
in death, electric shock, serious injury, fire, or damage.

• The icemaker requires an independent power supply of proper capacity. See the 

nameplate for electrical specifications. Failure to use an independent power supply 
of proper capacity can result in a tripped breaker, blown fuse, damage to existing 
wiring, or component failure. This could lead to heat generation or fire.

• 

THE ICEMAKER MUST BE GROUNDED. Failure to properly ground the icemaker 

could result in death or serious injury. 

• To reduce the risk of electric shock, do not touch the control switch with damp 

hands.

• Move the control switch to the "OFF" position and turn off the power supply before 

servicing. Lockout/Tagout to prevent the power supply from being turned back on 
inadvertently.

• Do not make any alterations to the appliance. Alterations could result in electric 

shock, injury, fire, or damage.

• The appliance is not intended for use by persons (including children) with reduced 

physical, sensory, or mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the 
appliance by a person responsible for their safety.

Содержание KMD-860MAJ

Страница 1: ...Models KMD 860MAJ MWJ MRJ Modular Crescent Cuber Instruction Manual Issued 1 16 2018 hoshizakiamerica com...

Страница 2: ...per installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist...

Страница 3: ...MD 860MRJ 10 II Installation and Operating Instructions 11 A Location 11 B Checks Before Installation 11 C How to Remove Panels 12 D Setup 13 E Electrical Connection 14 F Water Supply and Drain Connec...

Страница 4: ...ed in accordance with applicable national state and local codes and regulations Electrical connection must be hard wired and must meet national state and local electrical code requirements Failure to...

Страница 5: ...t and disconnect if required must meet national state and local electrical code requirements Failure to meet these code requirements could result in death electric shock serious injury fire or damage...

Страница 6: ...230 60 1 208 230 60 1 Compressor 208 230V 7 7RLA 46LRA 208 230V 7 2RLA 46LRA 208 230V 8 2RLA 56LRA Pump 120V 0 5FLA 60W 120V 0 5FLA 60W 120V 0 5FLA 60W Fan 120V 1 0FLA TOTAL 1 15HP 120V 3A MAX Fan in...

Страница 7: ...AJ NOTICE Allow 6 15 cm clearance at rear sides and top for proper air circulation and ease of maintenance and or service should they be required The storage bin opening must match the bottom opening...

Страница 8: ...at rear sides and top for proper air circulation and ease of maintenance and or service should they be required The storage bin opening must match the bottom opening as in the illustration KMD 860MWJ...

Страница 9: ...rear sides and top for proper air circulation and ease of maintenance and or service should they be required The storage bin opening must match the bottom opening as in the illustration KMD 860MRJ A...

Страница 10: ...mm in Rear Top Icemaker Model URC 9F Heat of Rejection AT 90 F 32 C WT 70 F 21 C KMD 860MRJ 11 200 BTU hr NOTICE Allow 24 61 cm clearance at front and rear for proper air circulation and ease of main...

Страница 11: ...the icemaker if the air temperature is going to go below 32 F 0 C See IV Preparing the Icemaker for Periods of Non Use The icemaker should not be located next to ovens grills or other high heat produc...

Страница 12: ...ote condenser unit listed below is recommended Connection to a different remote condenser unit will void the warranty unless Hoshizaki approves a different remote condenser unit for your specific appl...

Страница 13: ...top of the dispenser unit ice storage bin 6a Dispenser Unit Follow the dispenser unit adapter kit or top kit instructions for securing the icemaker If no instructions are available secure the icemaker...

Страница 14: ...ith the pig tail leads in the junction box See Fig 3 Additional Warnings for Remote Models THE REMOTE CONDENSER UNIT MUST BE GROUNDED Power supply and ground connection to the remote condenser unit ar...

Страница 15: ...ternal filters strainers or softeners may be required depending on water quality Contact your local Hoshizaki Certified Service Representative or local Hoshizaki distributor for recommendations A plum...

Страница 16: ...r supply line and drain line for the appliance to be pulled out for service Fig 4 Icemaker Icemaker Water Supply Inlet 1 2 FPT Bin Drain Outlet 3 4 FPT Icemaker Drain Outlet 3 4 FPT Ice Storage Bin Ic...

Страница 17: ...condenser drain outlet temperature is not in the proper range use a flat blade screwdriver to rotate the adjustment screw on the water regulating valve until the temperature is in the proper range ro...

Страница 18: ...in the 104 F to 115 F 40 C to 46 C range Once the icemaker installation is complete confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts If the condenser return outle...

Страница 19: ...t is intended for outdoor use Normal operating ambient temperature must be within 20 F to 122 F 29 C to 50 C Operation of the remote condenser unit for extended periods outside of this normal temperat...

Страница 20: ...r each meter over 20 m Write new total charge on icemaker s rating label 2 Checks Before Installation 1 Remove the shipping carton tape and packing material 2 Check that the refrigerant lines do not r...

Страница 21: ...he male fitting and female coupling b Apply Polyol Ester POE refrigerant oil or Parker Super O Lube to the entire male fitting including O ring diaphragm and threads before making the connection See F...

Страница 22: ...the icemaker Leave a service loop behind the icemaker to allow the icemaker to be pulled out for service See Fig 10 NOTICE Ensure that there are no traps and no kinks in the line set The service loop...

Страница 23: ...re male fitting including O ring diaphragm and threads before making the connection See Fig 11 NOTICE Do not use thread sealant on the fittings Use POE refrigerant oil or Parker Super O Lube only Coup...

Страница 24: ...x to the leads in the remote condenser unit junction box Use wire of an appropriate gage and outdoor rating Do not connect the fan motor leads in the icemaker to incoming power source Do not connect t...

Страница 25: ...5 Replace the junction box covers and the louver panel in their correct positions 7 Stacking Remote Condenser Unit 1 Install the lower remote condenser unit as described earlier in this section 2 Pla...

Страница 26: ...7 Are the water supply and drain lines sized as specified Are the water supply line shut off valve s and drain valve s installed Has the water supply pressure been checked to ensure a minimum of 10 PS...

Страница 27: ...or a total of 10 minutes 6 Turn off the power supply then remove the front panel 7 Remove the insulation panel then remove splash guard cube guide B and cube guide A Next remove the overflow cap overf...

Страница 28: ...pliance To reduce the risk of electric shock do not touch the control switch with damp hands Before Servicing Move the control switch to the OFF position and turn off the power supply Lockout Tagout t...

Страница 29: ...h containing a neutral cleaner to wipe off oil or dirt build up Clean any chlorine staining rust colored spots using a non abrasive cleanser Underside of Icemaker and Top Kits Bin Door and Snout Wipe...

Страница 30: ...The cleaning valve is opened during cleaning and sanitizing to allow solution flow to the inside of the evaporator It should be closed for all icemaking operation The compressor will not operate unle...

Страница 31: ...on panel then remove splash guard cube guide B and cube guide A Remove the overflow cap overflow pipe water shield and drain plug After the water tank has drained replace the drain plug water shield o...

Страница 32: ...guide A Remove the overflow cap overflow pipe water shield and drain plug After the water tank has drained replace the drain plug water shield overflow pipe overflow cap cube guide A cube guide B spla...

Страница 33: ...rtical open Move the control switch to the WASH position then replace the front panel After 5 min remove the front panel then move the control switch to the OFF position 27 Remove the front insulation...

Страница 34: ...tach a compressed air or carbon dioxide supply to the icemaker water supply line drain valve 6 Move the control switch to the ICE position 7 Replace the front panel in its correct position then turn o...

Страница 35: ...ine drain valve If connected to a closed loop system also open the condenser return line drain valve 4 Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve 5...

Страница 36: ...osal The icemaker contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service...

Страница 37: ...37 618 Hwy 74 South Peachtree City GA 30269 USA P 770 487 2331 F 770 487 3360 hoshizakiamerica com 1A4871 010...