Hoshizaki KMD-460MAJ Скачать руководство пользователя страница 17

17

F. Water Supply and Drain Connections

See Figs. 8 through 10

 WARNING

Water supply and drain connections must be installed in accordance with applicable 
national, state, and local regulations.

NOTICE

• Normal operating water temperature should be within 45°F to 90°F (7°C to 

32°C). Operation of the appliance, for extended periods, outside of this normal 
temperature range may affect appliance performance.

• Water supply pressure must be a minimum of 10 PSIG and a maximum of 

113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve 
is required.

• To prevent damage to the appliance, do not operate the appliance when the water 

supply is off, or if the pressure is below 10 PSIG. Do not run the appliance until 
the proper water pressure is reached.

• External filters, strainers, or softeners may be required depending on water quality. 

Contact your local Hoshizaki Certified Service Representative or local Hoshizaki 
distributor for recommendations.  

• A plumbing permit and services of a licensed plumber may be required in some areas.
• The icemaker drain line, dispenser unit/ice storage bin drain line, and water-cooled 

condenser drain line (if applicable) must be run separately. 

• Drain lines must have 1/4" fall per foot (2-cm per 1 m) on horizontal runs to get a good 

flow. A vented tee connection is also required for proper flow.

• Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 

2 vertical inches (5-cm) should be between the end of the drain pipes from the icemaker, 
dispenser unit/ice storage bin, and water-cooled condenser (if applicable) and the floor 
drain.

Содержание KMD-460MAJ

Страница 1: ...Models KMD 460MAJ MWJ KMD 530MAJ MWJ MRJ Modular Crescent Cuber Instruction Manual Issued 4 16 2019 hoshizakiamerica com...

Страница 2: ...per installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist...

Страница 3: ...ation and Operating Instructions 11 A Location 11 B Checks Before Installation 11 C How to Remove Panels 12 D Setup 13 1 Dispenser Unit Ice Storage Bin and Icemaker Setup 13 2 Bin Control Installation...

Страница 4: ...n accordance with applicable national state and local codes and regulations Electrical connection must be hard wired and must meet national state and local electrical code requirements Failure to meet...

Страница 5: ...t and disconnect if required must meet national state and local electrical code requirements Failure to meet these code requirements could result in death electric shock serious injury fire or damage...

Страница 6: ...ada Only 15 AMPS 15 AMPS Minimum Circuit Ampacity 15 AMPS 15 AMPS Design Pressure HI 467PSI LO 230PSI HI 427PSI LO 230PSI Refrigerant 404A 1 LB 5 OZ 404A 14 1 OZ 2 KMD 530M_J Single Phase Model Number...

Страница 7: ...they be required The storage bin opening must match the bottom opening as in the illustration KMD 460MAJ KMD 530MAJ A 768 30 1 4 B 761 30 C 498 19 5 8 D 103 4 E 201 7 7 8 F 173 6 3 4 G 117 4 5 8 H 54...

Страница 8: ...y be required The storage bin opening must match the bottom opening as in the illustration KMD 460MWJ KMD 530MWJ A 768 30 1 4 B 761 30 C 498 19 5 8 D 103 4 E 201 7 7 8 F 173 6 3 4 G 117 4 5 8 H 54 2 1...

Страница 9: ...ning as in the illustration ICEMAKER WATER INLET 1 2 FPT ELECTRICAL SUPPLY OPENING 22 7 8 DIA C 24 0 9 80 3 1 8 80 3 1 8 A B D F G E 10 3 8 507 20 562 22 1 8 332 13 1 8 H I J K L CONDENSER WATER INLET...

Страница 10: ...f Rejection AT 90 F 32 C WT 70 F 21 C KMD 530MRJ 8 500 BTU hr NOTICE Allow 24 61 cm clearance at front and rear for proper air circulation and ease of maintenance and or service should they be require...

Страница 11: ...revent damage to the water supply line drain the icemaker if the air temperature is going to go below 32 F 0 C See IV Preparing the Icemaker for Periods of Non Use The icemaker should not be located n...

Страница 12: ...30 wide or wider The following are recommended Hoshizaki Dispenser Model DB 200 or DM series Hoshizaki Ice Storage Bin Model B 500 series For further options contact your local Hoshizaki distributor...

Страница 13: ...5 Place the icemaker on top of the dispenser unit ice storage bin NOTICE Do not use the side frame to lift the icemaker See Fig 1 Lift the icemaker from the base 6a Dispenser Unit Follow the dispense...

Страница 14: ...control or bin control cable slide the water tank cube guide and pump motor and float switch assembly out of the icemaker Fig 3 Thumbscrews Insulation Panel B Pump Motor Connector Float Switch Connect...

Страница 15: ...e Dispenser or Dispenser Unit with Thick Adapter Application Bin Control Fig 6 Thumbscrews from Accessory Bag Extension Bracket from Accessory Bag Thumbscrews from Rear Interior Wall 8 Replace the wat...

Страница 16: ...the junction box See Fig 7 Additional Warnings for Remote Models THE REMOTE CONDENSER UNIT MUST BE GROUNDED Power supply and ground connection to the remote condenser unit are supplied from the icemak...

Страница 17: ...n the appliance until the proper water pressure is reached External filters strainers or softeners may be required depending on water quality Contact your local Hoshizaki Certified Service Representat...

Страница 18: ...n line for the appliance to be pulled out for service Fig 8 Icemaker 2 5 cm air gap Floor Drain Ice Storage Bin Model Shown KMD 460MAJ Minimum 3 4 Nominal ID Hard Pipe or Equivalent Air Cooled and Rem...

Страница 19: ...freeze cycle starts If the condenser drain outlet temperature is not in the proper range use a flat blade screwdriver to rotate the adjustment screw on the water regulating valve until the temperatur...

Страница 20: ...C to 46 C range Once the icemaker installation is complete confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts If the condenser return outlet temperature is not in t...

Страница 21: ...er unit for extended periods outside of this normal temperature range may affect appliance performance The maximum line length for the standard line sizes and refrigerant charge is 66 20 m With larger...

Страница 22: ...ixing of refrigerants will result in improper operation and possible damage to the refrigeration system Line Set Size and Refrigerant Charge Hoshizaki Icemaker Hoshizaki Remote Condenser Unit Line Set...

Страница 23: ...ng diaphragm and threads before making the connection See Fig 15 NOTICE Do not use thread sealant on the fittings Use POE refrigerant oil or Parker Super O Lube only Couplings are one time use only c...

Страница 24: ...the icemaker Leave a service loop behind the icemaker to allow the icemaker to be pulled out for service See Fig 14 NOTICE Ensure that there are no traps and no kinks in the line set The service loop...

Страница 25: ...t of the threads on the male fitting NOTICE Failure to use a backup wrench may result in damage to the line set and possible refrigerant leaks e Mark a reference line on the female coupling and the re...

Страница 26: ...x to the leads in the remote condenser unit junction box Use wire of an appropriate gage and outdoor rating Do not connect the fan motor leads in the icemaker to incoming power source Do not connect t...

Страница 27: ...5 Replace the junction box covers and the louver panel in their correct positions 7 Stacking Remote Condenser Unit 1 Install the lower remote condenser unit as described earlier in this section 2 Pla...

Страница 28: ...nit 7 Are the water supply and drain lines sized as specified Are the water supply line shut off valve s and drain valve s installed Has the water supply pressure been checked to ensure a minimum of 1...

Страница 29: ...ition 5 Turn on the power supply and allow the icemaker to operate for a total of 10 minutes 6 Remove the front panel then move the service switch to the DRAIN position 7 Replace the front panel in it...

Страница 30: ...anitation regulations Maintenance Schedule Frequency Area Task Daily Scoop Clean the ice scoop using a neutral cleaner Rinse thoroughly after cleaning Bi Weekly Air Filters Inspect Wash with warm wate...

Страница 31: ...position 1 Cleaning Procedure 1 Dilute 9 5 fl oz 281 ml of Hoshizaki Scale Away with 1 8 gal 6 8 l of warm water 2 Remove all ice from the evaporator and the dispenser unit ice storage bin Note To rem...

Страница 32: ...not to bend the retainer rod excessively when removing it h Wipe down the float switch housing shaft float and retainer rod with cleaning solution Rinse the parts thoroughly with clean water i Reassem...

Страница 33: ...l 32 Repeat steps 18 through 31 three more times to rinse thoroughly Note If you do not sanitize the icemaker go to step 14 in 2 Sanitizing Procedure 2 Sanitizing Procedure Following Cleaning Procedur...

Страница 34: ...e the front panel in its correct position 16 Clean the dispenser unit storage bin liner using a neutral cleaner Rinse thoroughly after cleaning 17 Turn on the power supply to start the automatic icema...

Страница 35: ...alve 6 Move the control switch to the ICE position 7 Replace the front panel in its correct position then turn on the power supply 8 Blow the icemaker water supply line out using compressed air or car...

Страница 36: ...to the condenser water supply line drain valve 5 Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring While holding the valve open blow out the...

Страница 37: ...sal The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service...

Страница 38: ...38 HOSHIZAKI AMERICA INC 618 Hwy 74 S Peachtree City GA 30269 USA TEL 770 487 2331 FAX 770 487 3360 www hoshizaki com 1A5714 010...

Отзывы: