Hoshizaki KM-520MAJ-E Скачать руководство пользователя страница 3

3

• Factory fitted power cords are coloured in accordance with 

the following code:

Green and Yellow = Ground (Earth)
Blue = Neutral
Brown = Line

For the UK and the Republic of Ireland Only

For Models with a Plug:
• The non-rewirable plug must never be used without a fuse 

cover being fitted.

• The correct replacement for the detachable fuse cover 

is identifiable from the manufacturer’s reference number 
stamped on the plug.

• Supply of replacement fuse covers can be obtained from 

Hoshizaki Parts/Service Centres.

• Fuses should be rated at 13A and approved to BS 1362.

C. Water Supply and Drain Connections

   WARNING

1. Water supply and drain connections must be 

installed in accordance with applicable national, 
state, and local regulations.

2. The icemaker water supply must be potable water.
3. Normal operating water temperature should be 

within 45°F to 90°F (7°C to 32°C). Operation of 
the icemaker, for extended periods, outside of this 
normal temperature range may affect icemaker 
performance.

4. Water supply pressure should be a minimum of 

10 PSIG (0.7 bar) and a maximum of 113 PSIG 
(7.8 bar). If the pressure exceeds 113 PSIG (7.8 bar), 
the use of a pressure reducing valve is required. 
DO NOT throttle back the supply tap.

5. To prevent damage to equipment, do not operate 

the icemaker when the water supply is off, or if the 
pressure is below 10 PSIG (0.7 bar). Do not run the 
icemaker until the proper water pressure is reached.

• A plumbing permit and services of a licensed plumber may 

be required in some areas.

• External filters, strainers, or softeners may be required 

depending on water quality. Contact your local Hoshizaki 
distributor for recommendations.

• Drain lines should not be piped directly to the sewer 

system. An air gap of a minimum of 2 vertical inches 
(5 cm) should be between the end of the drain pipes from 
the icemaker and condensation drain and ice storage bin 
and the floor drain.

I. Installation

Installation must be carried out by qualified service 
personnel in accordance with the Installation Manual 
supplied with this icemaker. The owner/manager should 
also be aware of the installation-related information 
below. 

   WARNING

1. This icemaker must be installed in accordance with 

applicable national, state, and local regulations.

2. 

CHOKING HAZARD:

 Installer must ensure all 

components, fasteners, and thumbscrews are 
securely in place after installation. Make sure that no 
components, fasteners, or thumbscrews have fallen 
into the ice storage bin. 

A. Location

NOTICE

1. This icemaker is not intended for outdoor use. 

Normal operating ambient temperature should 
be within 45°F to 100°F (7°C to 38°C); Normal 
operating water temperature should be within 
45°F to 90°F (7°C to 32°C). Operation of the 
icemaker, for extended periods, outside of these 
normal temperature ranges may affect icemaker 
performance.

2. This icemaker will not work at sub-freezing 

temperatures. To prevent damage to the water 
supply line, have a qualified service technician drain 
the icemaker if the air temperature is going to go 
below 32°F (0°C).

3. Do not place anything in front of the louver(s) 

(air-cooled models).

B. Electrical Connection

   WARNING

1. Electrical connection must meet national, state, and 

local electrical code requirements. Failure to meet 
these code requirements could result in death, 
electric shock, serious injury, fire, or severe damage 
to equipment.

2. This unit requires an independent power supply of 

proper capacity. See the nameplate for electrical 
specifications. Failure to use a properly sized 
breaker or fuse can result in a tripped breaker, 
blown fuses, or damage to existing wiring. This 
could lead to heat generation or fire.

3. 

THIS UNIT MUST BE GROUNDED (EARTHED). 

Failure to properly ground (earth) this unit could 
result in death or serious injury.

• Usually an electrical permit and services of a licensed 

electrician are required.

• If a power cord and/or a plug should need to be fitted/

replaced, it should only be done by a qualified service 
technician.

Отзывы: