Sanitizing
14) To fill the water tank, turn the cleaning valve to the right until completely horizontal
(closed). Move the control switch to the "ICE" position, then replace the front panel.
After 3.5 min., remove the front panel, then move the control switch to the "OFF"
position.
15) Remove the front insulation panel, then pour 50 ml of an 8.25% sodium hypochlorite
solution (chlorine bleach) into the water tank. Replace the front insulation panel.
Turn the cleaning valve to the left until completely vertical (open).
IMPORTANT!
Use
regular bleach with no additives. Using a bleach with additives causes excessive
foaming during sanitizing, reducing the effectiveness of sanitizing.
16)
NOTICE!
To avoid excessive foaming, wait 1 min. before proceeding.
After 1 min., move the control switch to the "WASH" position, then replace the front
panel.
17) After 45 min., remove the front panel, then move the control switch to the "OFF"
position.
18) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe.
After the water tank has drained, reconnect the overflow pipe. Replace the rubber
hose, overflow cap, cube guide, and front insulation panel.
Sanitizing Rinse 1
19) Turn the cleaning valve to the right until completely horizontal (closed). Move the
control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove
the front panel, then move the control switch to the "OFF" position.
20) Turn the cleaning valve to the left until completely vertical (open). Move the control
switch to the "WASH" position, then replace the front panel. After 5 min., remove the
front panel, then move the control switch to the "OFF" position.
21) Remove the front insulation panel, then slide the cube guide to the right. Remove the
rubber cap and sleeve covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber hose, overflow
cap, cube guide, and front insulation panel.
Sanitizing Rinse 2
22) Turn the cleaning valve to the right until completely horizontal (closed). Move the
control switch to the "ICE" position, then replace the front panel. After 3.5 min., remove
the front panel, then move the control switch to the "OFF" position.
23) Turn the cleaning valve to the left until completely vertical (open). Move the control switch to
the "WASH" position, then replace the front panel. After 5 min., remove the front panel, then
move the control switch to the "OFF" position.
24) Remove the front insulation panel, then slide the cube guide to the right. Remove the rubber
hose and overflow cap covering the overflow pipe. Unscrew the overflow pipe. After the
water tank has drained, reconnect the overflow pipe. Replace the rubber hose, overflow
cap, cube guide, and front insulation panel.