8
ENGLISH
Code
Item
Description
Default
U.44
Automatic water cleaning
frequency
0: No automatic water cleaning
5: Every 5 cycles
10: Every 10 cycles
15: Every 15 cycles
20: Every 20 cycles
40: Every 40 cycles
60: Every 60 cycles
20: Every 20
cycles
U.49
Number of chemical doses (*)
When chemical doses reach set number of times, notice code
"n93" appears to show no chemical is left.
KM-40: 15 times
KM-60: 13 times
KM-80: 12 times
KM-140: 16 times
U.50
Fully automated chemical
cleaning frequency (*)
Start fully automated chemical cleaning at set frequency.
Adjustable from every 400 to 1000 cycles (in 100-cycle steps)
e.g. 40 = 400 cycles
–
U.51
UV-LED irradiation time (**)
Irradiate UV-LED for set period of time.
None or adjustable from 10 to 30 minutes (in 1-minute steps)
–
U.52
UV-LED irradiation frequency (**) Irradiate UV-LED in freeze cycle after set period of time.
Adjustable from 30 to 300 minutes (in 10-minute steps)
120 minutes
U.53
Operation mode
nor: Normal mode
cln: Sanitation mode (After 4 continued hours of inactivity,
water circuit is automatically cleaned and refreshed to prevent
bacterial proliferation.)
nor: Normal mode
U.54
Fully automated chemical
cleaning mode (*)
When "cln" (sanitation mode) is selected, unit runs one cycle
of fully automated chemical cleaning by using fully automated
cleaning kit (option) regardless of frequency set by U.50.
–
U.55
Reset number of chemical doses
(*)
Reset notice code “n93” (no chemical is left) and number of
chemical doses.
–
U.56
Reset settings
Reset all user settings to default.
–
U.58
Forced shut down
Shut down unit under any conditions.
–
U.59
Forced drain
Shut down and drain unit under any conditions.
–
U.60
Notice (e.g. maintenance)
Notice code “n99” appears after set period of time.
Adjustable from 0 (none) to 6000 hours (in 100-hour steps)
0: None
U.68
Reset notice
Reset counting for notice U.60.
–
* Applicable only to the fully automated cleaning model (-W) or when the fully automated cleaning kit (option) is used.
** Applicable only when the UV-LED (option) is used.
3. PREPARING THE ICEMAKER FOR LONG STORAGE
NOTICE
This icemaker will not work at subfreezing temperatures. To prevent damage to the water supply line, drain the icemaker when
air temperature is below zero.
HYGIENE
When shutting down the icemaker for two or more days, drain the icemaker to prevent contamination in the water circuit.
1) Press the ON/OFF buton. The display shows “oFF”.
2) Press and hold the reset button for 3 seconds to enter the user setting mode.
3) Set the user setting “U.59” to “1” to drain the icemaker.
4) Unplug the icemaker or disconnect the power supply.
5) Close the water supply tap, and remove the inlet hose.
6) Remove all ice from the storage bin, and clean the bin.