33
Fig. 21
Bin Control Lens
Compressor Base
Icemaker
Control Switch
Mode Switch
Fig. 20
3) Move the mode switch on the control box to the "ICE" position, then move the control
switch to the "ON" position. Turn on the power supply, and allow the icemaker to operate.
4) Confirm the control board "BC OPEN/CLOSED" LED is off (bin empty) and the bin
control controller "LED 1" LED is on (bin empty). See Fig. 20.
Ice Level in Bin
Control Board "BC
OPEN/CLOSED" LED
Bin Control Controller
"LED 1" LED
Empty
OFF
ON
Full
ON
OFF
Control Board
BC OPEN/
CLOSED LED
Bin Control Controller
LED 1
Factory Setting
5) If the bin control controller LED 1 is off (indicating a full bin), the control board BC
OPEN/CLOSED LED should be on (indicating a full bin). If so, correct any interference
from the top kit or top kit riser (if applicable).
6) Move the control switch to the "OFF" position, wait 2 min., then move the control switch
to the "ON" position. 1 min. fill cycle begins. Place an object 5" to 7" (127 to 178 mm)
away from the bin control lens. See Fig. 21. 15 sec. later, the icemaker shuts down.
Remove the object from the bin control lens. 30 sec. later, the icemaker restarts.
For bin control shutdown times per cycle, see the table below.
Cycle at Bin
Control Activation Shutdown
1 min. Fill Cycle
15 sec. after activation.
Harvest Cycle
If engaged 15 sec. or longer, at the end of harvest cycle.
Freeze Cycle
15 sec. after activation if activated at least 15 sec. before the 5-min. short cycle
protection timer terminates. Otherwise, at the end of the next harvest cycle.
7) Once the icemaker restarts, move the control switch to the "OFF" position, then turn off
the power supply.
8) Return to step 10 in "I. Startup."