62
2. Sanitizing Procedure - Following Cleaning Procedure
1) Mix 3 gallons (11.4 l) of water and 1.5 fl. oz. (44.4 ml) of a 5.25% sodium hypochlorite
solution (chlorine bleach).
2) Complete steps 2) through 7) as detailed in “1. Cleaning Procedure.”
3) Pour the sanitizing solution into the water tank.
4) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure that the control switch is in the “WASH” position.
5) Turn on the power supply, and start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the front panel.
8) Drain the water tank. See step 6) in “1. Cleaning Procedure.”
9) Refit the pump tubing in its correct position.
10) Repeat the above steps 16) through 27) in “1. Cleaning Procedure” two times to rinse
thoroughly.
11) Move the control switch to the “ICE” position.
12) Replace the front panel and the base cover in their correct positions.
13) Clean the storage bin with water.
14) Turn on the power supply, and start the automatic icemaking process.