54
12) Clean the storage bin with water.
13) Turn on the power supply, and start the automatic icemaking process.
B. Maintenance
IMPORTANT
This icemaker must be maintained individually, referring to the instruction
manual and labels provided with the icemaker.
1. Stainless Steel Exterior
To keep the exterior clean, wipe occasionally with a clean and soft cloth. Use a damp
cloth containing a neutral cleaner to wipe off oil or dirt build up.
2. Storage Bin and Scoop
• Wash your hands before removing ice. Use the plastic scoop provided (Accessory).
• The storage bin is for ice use only. Do not store anything else in the bin.
• Keep the scoop clean. Clean it by using a neutral cleaner and rinse thoroughly.
• Clean the bin liner by using a neutral cleaner. Rinse thoroughly after cleaning.
3. Air Filters (air-cooled model only)
The plastic mesh air filters located behind the louvers remove dirt or dust from the air,
and keep the condenser from getting clogged. As the filters get clogged, the icemaker’s
performance will be reduced. Check the filters at least twice a month. When they are
clogged, use warm water and a neutral cleaner to wash the filters.
4. Condenser (air-cooled and remote air-cooled models only)
Check the condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
icemaker or condenser unit.
C. Preparing the Icemaker for Long Storage
IMPORTANT
When shutting off the icemaker for an extended time, drain out all water from
the water tank and remove the ice from the storage bin. The storage bin should
be cleaned and dried. Drain the icemaker to prevent damage to the water
supply line at sub-freezing temperatures, using air or carbon dioxide. Shut off
the icemaker until the proper ambient temperature is resumed.
When the icemaker is not used for two or three days, it is sufficient to move the control
switch to the "OFF" position, unless the icemaker will be at sub-freezing temperatures.
1. Remove the water from the water-cooled condenser (water-cooled model only):
1) Remove the front panel.
2) Move the control switch on the control box to the "OFF" position.
Содержание KM-1340MAH
Страница 8: ...8 B Condensing Unit 1 URC 14F ...
Страница 10: ...10 II General Information A Construction 1 KM 1340MAH air cooled ...
Страница 11: ...11 2 KM 1340MWH water cooled ...
Страница 12: ...12 3 KM 1340MRH remote air cooled ...
Страница 23: ...23 III Technical Information A Water Circuit and Refrigeration Circuit 1 KM 1340MAH air cooled ...
Страница 24: ...24 2 KM 1340MWH water cooled ...
Страница 25: ...25 3 KM 1340MRH remote air cooled ...
Страница 27: ...27 2 KM 1340MRH remote air cooled Pressure Switch Cut out 412 21 3 PSIG Cut in 327 21 3 PSIG ...