28
3) Press the
unmarked, blank button to display the current setting. Press the
up or
down button to increase or decrease the defrost termination temperature.
Note: The defrost termination temperatures can be adjusted within the following ranges:
• Refrigerator: 59 to 68°F (15 to 20°C) in one degree increments
• Freezer: 41 to 68°F (5 to 20°C) in one degree increments
4) Press the
unmarked, blank button to save the setting.
5) Press the MANUAL DEFROST button to return to the menu screen. Press and hold
both the
button and the
unmarked, blank button for 5 seconds to exit the setting
mode and return to the temperature display.
6) If a jumper was present between connector K151 pins 7 and 8, reconnect it after all
setting and diagnostic work is complete.
c) Setpoint Temperature Differential (F2)
To change the differential, follow the steps below.
1) Make sure the jumper is removed between connector K151 pins 7 and 8 on the control
board. Otherwise you will not be able to access this setting. For details, see "D.1.
Gaining Access to Settings and Diagnostics."
2) Press and hold both the
button and the
unmarked, blank button for 5 seconds.
"F0" should appear in the display window. Press the MANUAL DEFROST button until
"F2" appears in the display window.
3) Press the
unmarked, blank button to display the c setting (the decimal
between the digits is not shown). Press the
up or
down button to increase or
decrease the + (plus) differential in .9°F increments.
Note:
• Both the + and - values can be adjusted between 0.0 and 6.3°F in .9°F increments
(0.0 to 3.5°C in .5°C increments).
• You cannot set both + and - to 0.0.
4) Press the
unmarked, blank button to save the + setting and move to the - (minus)
differential setting.
5) Press the
up or
down button to increase or decrease the - (minus) differential in
.9F increments.
Note:
• Both the + and - values can be adjusted between 0.0 and 6.3°F in .9°F increments
(0.0 to 3.5°C in .5°C increments).
• You cannot set both + and - to 0.0.
6) Press the
unmarked, blank button to save the - (minus) setting. The - (minus) sign
will turn off and the display will change to the + (plus) differential setting.
7) Press the MANUAL DEFROST button to return to the menu screen. Press and hold
both the
button and the
unmarked, blank button for 5 seconds to exit the setting
mode and return to the temperature display.
8) If a jumper was present between connector K151 pins 7 and 8, reconnect it after all
setting and diagnostic work is complete.
Содержание HUF40A
Страница 6: ...6 Units mm in 1a HUR40A D HUF40A D 1 HUR40A HUF40A ...
Страница 7: ...7 2 HWR40A HWF40A Units mm in 2a HWR40A D HWF40A D ...
Страница 8: ...8 3 HUR68A HUF68A Units mm in 3a HUR68A D HUF68A D ...
Страница 9: ...9 4 HWR68A HWF68A Units mm in 4a HWR68A D HWF68A D ...
Страница 10: ...10 5 HUR96A 5a HUR96A D Units mm in ...
Страница 11: ...11 6a HWR96A D 6 HWR96A Units mm in ...