3. DRAIN PIPE CONNECTION

NOTICE

Be sure to connect the drain hoses properly. Otherwise water leaks from the drain hoses may 

damage the surroundings (property).

IMPORTANT

Drain lines shall be as short and straight as possible. The drain hoses shall have an adequate 

pitch or fall so that no part is higher than the drain outlets.

To  prevent  a  backflow,  do  not  connect  the  drain 

hoses directly with the sewer system. An air gap of 

a minimum of 5 cm should be between the ends of 

the drain hoses and the water level of drainage.

When  installing  more  than  two  units,  do  not 

interconnect their drain hoses. If the interconnection 

is necessary, provide an air inlet per unit.

● The drain outlets are at the bottom of the body. Use the accessories to connect the drain hoses.

●  HRFE  type  is  provided  with  two  defrost  water  drain  outlets  while  HRE  and  HFE  types  are 

provided with only one.

1) Insert  the  18  mm  diameter  end  of  flexible  hose  into  the 

defrost  water  drain  outlet,  and  fix  the  flexible  hose  with 

the accessory drain hose band.

2) Attach  the  other  end  (26  mm  outer  diameter)  of  the 

flexible hose to the drainage.

5 cm or more

Water Level

5 cm or more

Air Inlet

Water Level

Flexible Hose

(end: 26

 

mm outer diameter)

Defrost Water Drain Outlet

(18 mm diameter)

The illustration above shows HRE or HFE

Содержание HRFE-77B-CHD

Страница 1: ...ower the temperature setting The temperature range given below is only the adjustable range The actual cabinet temperature depends on the ambient temperature and other conditions The cabinet temperature is factory adjusted to 3 C for the refrigerator and 18 C for the freezer If necessary readjust the temperature as follows 1 Open the front panel 2 Press the set point button for the refrigerator or...

Страница 2: ...ore than two units do not interconnect their drain hoses If the interconnection is necessary provide an air inlet per unit The drain outlets are at the bottom of the body Use the accessories to connect the drain hoses HRFE type is provided with two defrost water drain outlets while HRE and HFE types are provided with only one 1 Insert the 18 mm diameter end of flexible hose into the defrost water ...

Страница 3: ...用手册 2本 安装手册 1本 层板 4件 层板托 8件 层板支架 8件 排水软管组件 2件 2 柜内温度设置 重要 按温度控制按钮 向下 只能降低温度设定值 并不会起到加快制冷速度的作用 下文中的温度范围仅指可调节范围 柜内的实际温度取决于环境温度和其它条件 柜内温度在出厂时设为3 对于冷藏柜 和 18 对于冷冻柜 如果需要 请按照如下方法重新调节 温度 1 打开前面板 2 按冷藏柜或冷冻柜的设置点按钮显示当前设置点温度 3 按住设置点按钮 并按温度控制按钮 直至温度显 示窗显示所需的温度 可以在 6 和12 之间 对于 冷藏柜 以及 25 和 7 之间 对于冷冻柜 调节柜 内温度 4 显示的柜内温度被调节为与未放置食物时柜内中心 处的温度几乎相同 但根据存放的食物 柜门开启 频率或测量点不同 显示温度可能会与实际温度有 所不同 设置点按钮 温度显示窗 手动除 霜按钮 重置按钮 温度控 制...

Страница 4: ...口 为防止废水回流 请勿将排水软管直连至下水道系 统 而且 排水软管末端和排水水位之间应至少保 持5cm的间隙 当安装两台以上时 请勿将两者的排水软管进行互 连 若必需互连 则每台均需配备一个进风口 排水口位于机身的底部 请使用附件连接排水软管 HRFE型配备两个除霜水排放口 而HRE和HFE型则仅配备一个 1 将挠性软管一端 直径为18mm 插入除霜水排放口中 然后使 用排水软管卡箍附件固定挠性软管 2 将挠性软管的另一端 外径为26mm 悬垂至下水道处 5cm 以上 水位 5cm 以上 进风口 水位 挠性软管 端部 外径为 26mm 除霜水排放口 直径为18mm 以上为HRE或HFE图例 ...

Отзывы: