21
Temperature Alarm (Do Not Adjust)
Service Menu
Min.
Max.
Unit
Factory Setting
Description
A0
0
1
---
0
AL alarm sensor. Do not adjust.
0=cabinet thermistor
1=evaporator thermistor
A1
-99
99
°C/°F
-10
Degrees below setpoint for AL alarm
when A2=1. Do not adjust.
A2
0
2
---
1
AL alarm. Do not adjust.
0=deactivated
1=A1 relative to setpoint
(setpoint - A1)
2=absolute. AL occurs at
temperature A1.
A4
-99
99
°C/°F
10
Degrees above setpoint for AH
alarm when A5=1. Do not adjust.
A5
0
2
---
1
AH alarm. Do not adjust.
0=deactivated
1=A4 relative to setpoint
(se A4)
2=absolute. AH occurs at
temperature A4.
A6
0
240
min.
120
AH delay after startup.
Do not adjust.
A7
0
240
min.
120
Delay for AL or AH alarm to occur
after temperature is below A1 or
above A4.
Do not adjust.
A8
0
240
min.
15
AH delay after door switch closes.
Do not adjust.
A9
0
240
min.
15
AH delay after door switch opens. Do
not adjust.
A11
0.1
15
°C/°F
4
A1 and A4 temperature differential.
Do not adjust.