Hoshizaki HF-128MA-A Скачать руководство пользователя страница 9

ENGLISH

7

2) Under normal operating conditions, press the set 

key for 3 seconds to enter the user menu. When 

the screen displays “St”, press the set key again. 

The screen displays the value of “St”. It could be 

modified by pressing the up or down key (see 

IMPORTANT 2).

  After choosing the “St” menu, press the set key to 

set parameter value. Press the up or down key to 

adjust parameter value, and then repress the set 

key to go back to the menu choosing status.

  Under the setting status, press the defrost/reset 

key or perform no operation for 30 seconds. The 

system will save the parameters and exit from the 

parameter setting mode.

Code

Function

Set Range Default Unit

St Temperature setting

(refrigerator)

-6 to +12

1

°C

St Temperature setting

(freezer)

-7 to -23

-20

°C

Glass door model (HR series) Set temperature 

:-2°C to +12°C

IMPORTANT

1. The temperature setting must be between -6 

and 12°C for the refrigerator and between -7 

and -23°C for the freezer to prevent possible 

failure.

2. To avoid the risk of failure, do not make 

changes to other menus than “St”.

3. T h e  d i s p l a y e d  c a b i n e t  t e m p e r a t u r e 

is  adjusted  to  be  almost  equal  to  the 

temperature at the center of the cabinet 

without foods. But it can be different from 

the actual temperature depending on 

arrangement  of  stored  foods,  frequency  of 

door opening or measuring points.

The compressor stops when the cabinet temperature 

reaches down to the set temperature, and starts 

when the cabinet temperature rises to the set 

tempe 4°C. Accordingly, the average cabinet 

temperature will be around the set tempe 

2°C.

Set temperature (compressor off temperature)

 

Off-cycle defrost (HR series): -6 to +12°C

 

Heater defrost (HF series): -7 to -23°C

3. DEFROST

Automatic defrost cycle

The refrigerator/freezer automatically defrosts the 

evaporator 6 hours after the refrigeration starts. The 

defrost indicator light on the operation panel comes 

on when the defrost cycle starts.

Manual defrost cycle

To start the manual defrost cycle, press the defrost/

reset key for 3 seconds. The defrost indicator light 

on the operation panel comes on when the defrost 

cycle starts.

4. INDICATOR LIGHTS

Indicator Light  Symbol Status

Meaning

Setting

set

On

Parameter setting

Off

Measuring and 

controlling status

Refrigeration

On

Refrigerating

Off

Refrigeration stopped

Flash Refrigeration delayed

Defrost

On

Defrosting

Off

Defrost stopped

Fan

On

Fan running

Off

Fan stopped

Defrost dripping

drip On

Start defrost dripping

Off

Stop defrost dripping

5. SHUT DOWN

1) Before shutting down the unit, move the stored 

foods into another refrigerator/freezer.

2) Unplug the unit or disconnect the main power 

supply.

Fig. 13

Average Cabinet 

Temperature

Set Temperature

Compressor

ON

OFF

Time

4K

Interior Thermistor  Temperature

Содержание HF-128MA-A

Страница 1: ...tegral and essential part of the product and should be kept and preserved by the user Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer user with essential information for the proper installation and the continued safe use and maintenance of the product Please preserve this booklet for any further consultation that may be necessary Man...

Страница 2: ... 6 ELECTRICAL CONNECTIONS 4 7 DRAIN CONNECTIONS No Evaporting Pan Set Type 4 II OPERATING INSTRUCTIONS 5 1 START UP 6 2 CABINET TEMPERATURE SETTING 6 3 DEFROST 7 4 INDICATOR LIGHTS 7 5 SHUT DOWN 7 III MAINTENANCE 8 1 INTERIOR EXTERIOR SHELF 8 2 AIR FILTER 8 3 BEFORE CALLING A SERVICE AGENT 9 a TROUBLES WITH ERROR CODE INDICATION 9 b TROUBLES WITHOUT ERROR CODE INDICATION 9 4 DISPOSAL 9 5 WARRANTY ...

Страница 3: ...e proceeding with cleaning and maintenance operations make sure the power line of the unit is disconnected 8 Do not connect or disconnect the electric plug when your hands are wet 9 Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance 10 Do not store or use gasoline or any other flammable vapors and liquids 11 If the supply cord is damaged it must be...

Страница 4: ...damage the exterior panels Avoid a site where dripping is not allowed Especially a side by side or back to back installation possibly with other manufacturer s unit may cause condensation between the two units resulting in dripping onto the floor Do not expose the unit to direct sunlight or higher temperatures Allow at least 100 cm clearance at the front of the unit for smooth door operation Also ...

Страница 5: ...s as shown below Fig 7 Front Rear IMPORTANT Do not put anything at the bottom of the cabinet to prevent damage or deformation to the cabinet bottom resulting in corrosion 4 Position the unit in a selected site 5 Clean the interior with a soft cloth soaked in cold or w arm water containing t he p roper amount of neutral cleaner and wrung dry Caster models 6 Level t he r efrigerator freezer i n both...

Страница 6: ...ed power receptacle which is readily accessible and has enough capacity The maximum allowable voltage variation should not exceed 10 percent of the nameplate rating See the nameplate If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 7 DRAIN CONNECTIONS No Evaporting Pan Set Type CAUTION Be sure to conne...

Страница 7: ...r for 1 hour and check for proper temperature before putting foods in the cabinet 10 Do not block the air inlet outlet with foods 11 Do not pack the cabinet with foods Allow some space between them to ensure good air flow 12 Do not put in warm or hot foods Let them cool first or they will raise the cabinet temperature and could deteriorate other foods in the cabinet or overload the refrigerator fr...

Страница 8: ...d copper tubes resulting in failure 16 F o o d s i n t e n d e d f o r d i r e c t h u m a n consumption should be stored on the shelf in a proper container and protected from direct contact with the cabinet walls 17 Do not use the freezer to freeze foods It is designed only to store frozen foods High quality ice cream may melt during defrost cycle and should not be stored in the freezer 18 The do...

Страница 9: ...s frequency of door opening or measuring points The compressor stops when the cabinet temperature reaches down to the set temperature and starts when the cabinet temperature rises to the set temperature 4 C Accordingly the average cabinet temperature will be around the set temperature 2 C Set temperature compressor off temperature Off cycle defrost HR series 6 to 12 C Heater defrost HF series 7 to...

Страница 10: ...pecially detergent to clean grease on ventilator or microwave Note Some solutions other than the above may also damage painted or plastic surfaces The door gasket and its contact surface get soiled easily Clean every surface of these parts thoroughly Remnants of food will accelerate aging Use a cloth to wipe off any water staying inside the cabinet 2 AIR FILTER IMPORTANT To prevent deformation do ...

Страница 11: ...dity too high 2 Door s not closed tightly 4 Noise 1 Normal operating sounds of compressor or condenser fan 5 Frosting inside compartment 1 Ambient humidity too high 2 Door s opened too often 3 Too packed with foods beyond load line 4 DISPOSAL When disposing of the refrigerator freezer contact an authorized Hoshizaki service company or a specialized waste disposal company IMPORTANT The insulation f...

Страница 12: ...apore 609966 Tel 65 6225 2612 Fax 65 6225 3219 Hoshizaki Taiwan Inc 5F No 337 Sec 1 Dunhua S Rd Da an Dist Taipei City 106 Taiwan R O C Tel 886 2 2706 8818 Fax 886 2 2708 7999 Hoshizaki Lancer Pty Ltd 5 Toogood Avenue Beverley SA 5009 Australia Tel 61 8 8268 1388 Fax 61 8 8268 1978 info hoshizaki com au http www hoshizaki com au To register your product for warranty with Hoshizaki visit http www h...

Отзывы: