Hoshizaki FT-126MA-A Скачать руководство пользователя страница 5

ENGLISH

3

II. OPERATING INSTRUCTIONS

IMPORTANT

1. B e  c a r e f u l  n o t  t o  w e t  t h e  m a c h i n e 

compartment. This might cause failure or 

electric shock hazard.

2. To prevent electric shock, do not touch the 

attachment plug with wet hands.

3. Do not store any volatile or flammable 

substances such as benzine, ether, 

adhesives and LPG, or any explosive 

substances such as aerosol cans with a 

flammable propellant in the unit.

4. This refrigerator/freezer is designed only 

for temporary storage of foods. Use for any 

other purposes (e.g. storage of chemicals 

or medical supplies such as vaccine and 

serum) could cause deterioration of stored 

items.

5. Do not throw anything onto the shelves or 

load more than 60 kg on each of them. They 

may fall off and cause injury.

6. Do not store bottles or cans near the air 

outlet. They may freeze up and break, 

causing a risk of injury.

CAUTION

Attach the shelf clips properly to make the shelf 

level.

* To lay the shelf at the bottom of the cabinet, attach 

two shelf holders each to the left and right frames 

and one to the center frame as shown below.

IMPORTANT

When using the shelf at the bottom of the 

cabinet, be sure to use the shelf holders to 

prevent damage to the cabinet bottom, resulting 

in corrosion.

6. ELECTRICAL CONNECTIONS 

IMPORTANT

This refrigerator/freezer is provided with no 

power switch or earth leakage circuit breaker, 

but with overcurrent protection (fuse) only. 

Install a switch rated at least 10A on the main 

power supply.

* This refrigerator/freezer must be plugged into 

the separated power receptacle which is readily 

accessible and has enough capacity. The 

maximum allowable voltage variation should not 

exceed ± 10 percent of the nameplate rating. See 

the nameplate.

* If the supply cord is damaged, it must be replaced 

by the manufacturer, its service agent or similarly 

qualified persons in order to avoid a hazard.

Fig. 8

Fig. 7

Shelf Clip

Shelf Post

Push

Hook

CAUTION

The height of the adjustable legs must be within 

9 - 12 cm (or 15 - 18 cm for some models). 

If extended too much, the legs may become 

weak or the adjusters can come off, causing 

unexpected injuries.

5. SHELF, SHELF CLIP AND SHELF HOLDER

* The shelf is adjustable in 2.5 cm increments. Adjust 

the shelf clips according to the height of stored 

items.

* To attach the shelf clip, insert the upper tab into 

an adjust hole in the shelf post to hook the shelf 

clip, and push the lower tab into another adjust 

hole until it locks in place. To detach the shelf clip, 

reverse the above procedure.

Fig. 6

Adjustable Leg

Adjuster

Leg Height

Longer               Shorter

Содержание FT-126MA-A

Страница 1: ...TION MANUAL This booklet is an integral and essential part of the product and should be kept and preserved by the user Please read carefully the guidelines and warnings contained herein as they are intended to provide the installer user with essential information for the proper installation and the continued safe use and maintenance of the product Please preserve this booklet for any further consu...

Страница 2: ...ICAL CONNECTIONS 3 II OPERATING INSTRUCTIONS 3 1 START UP 4 2 CABINET TEMPERATURE SETTING 4 3 DEFROST 5 4 INDICATOR LIGHTS 5 5 SHUT DOWN 5 III MAINTENANCE 5 1 INTERIOR EXTERIOR SHELF 6 2 AIR FILTER 6 3 BEFORE CALLING A SERVICE AGENT 6 a TROUBLES WITH ERROR CODE INDICATION 7 b TROUBLES WITHOUT ERROR CODE INDICATION 7 4 DISPOSAL 7 5 WARRANTY 7 ...

Страница 3: ...nless they are of the type recommended by the manufacturer 7 Before proceeding with cleaning and maintenance operations make sure the power line of the unit is disconnected 8 Do not connect or disconnect the electric plug when your hands are wet 9 Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance 10 Do not store or use gasoline or any other flamma...

Страница 4: ...lly a side by side or back to back installation possibly with other manufacturer s unit may cause condensation between the two units resulting in dripping onto the floor Do not expose the unit to direct sunlight or higher temperatures Allow at least 50 cm clearance between the front panel air inlet outlet and the wall or other equipment for proper air circulation The front of the unit should have ...

Страница 5: ...lders to prevent damage to the cabinet bottom resulting in corrosion 6 ELECTRICAL CONNECTIONS IMPORTANT This refrigerator freezer is provided with no power switch or earth leakage circuit breaker but with overcurrent protection fuse only Install a switch rated at least 10A on the main power supply This refrigerator freezer must be plugged into the separated power receptacle which is readily access...

Страница 6: ...e refrigerator and 20 C for the freezer If necessary readjust the temperature as follows some space between them to ensure good air flow 12 Do not put in warm or hot foods Let them cool first or they will raise the cabinet temperature and could deteriorate other foods in the cabinet or overload the refrigerator freezer 13 Make sure all items are snug on each shelf 7 Do not use combustible spray or...

Страница 7: ...om the actual temperature depending on arrangement of stored foods frequency of door opening or measuring points III MAINTENANCE IMPORTANT 1 Before carrying out any cleaning or maintenance operations unplug the unit 2 D o n o t t o u c h o r w e t t h e m a c h i n e compartment parts This could result in failure or breakdown 3 To prevent possible damage do not clean the plastic parts with water a...

Страница 8: ... Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting clogged If the filters get clogged the refrigerator freezer s performance will be reduced Check the filter at least twice a month When clogged or when the temperature controller shows cH use warm water and a neutral cleaner to wash the filter Do not operate the unit with the air filter removed or the con...

Страница 9: ... Service office a TROUBLES WITH ERROR CODE INDICATION Code Possible Cause Remedy E1 Cabinet sensor error Immediately contact an authorized Hoshizaki service company E2 Evaporator sensor error E3 Condenser sensor error The code dEF is not an error code but indicates the unit is in defrost cycle b TROUBLES WITHOUT ERROR CODE INDICATION 1 Unit fails to operate 1 Unplugged 2 Power failure 3 Main power...

Страница 10: ...apore 609966 Tel 65 6225 2612 Fax 65 6225 3219 Hoshizaki Taiwan Inc 5F No 337 Sec 1 Dunhua S Rd Da an Dist Taipei City 106 Taiwan R O C Tel 886 2 2706 8818 Fax 886 2 2708 7999 Hoshizaki Lancer Pty Ltd 5 Toogood Avenue Beverley SA 5009 Australia Tel 61 8 8268 1388 Fax 61 8 8268 1978 info hoshizaki com au http www hoshizaki com au To register your product for warranty with Hoshizaki visit http www h...

Отзывы: