G. Diagnostic Tables
Before consulting the diagnostic charts, check for correct installation, proper voltage per
appliance nameplate, and adequate water supply. Check control board using the steps in
"II.C. Control Board Check."
1. No Ice Production
No Ice Production - Possible Cause
Startup
1. Power Supply-FS
a) Unplugged, off, blown fuse, or tripped breaker.
b) Not within specifications.
c) Loose connection.
d) Bad contacts.
Power Supply-SRC
a) Off, tripped breaker
b) Not within specifications.
c) Loose connection.
d) Bad contacts.
2. Water Supply
a) Water supply off or improper water pressure.
b) External water filters clogged.
3. Power Switch
a) "OFF" position.
b) Bad contacts.
4. Control Transformer
(115VAC/24VAC)
a) Coil winding open or shorted.
5. 1A Fuse (Control Box)
a) Blown.
6. Control Board
See "II.C. Control Board Check"
a) In alarm.
b) Defective
7. Control Switch
a) In "DRAIN" position.
b) Bad contacts.
8. BC (infrared sensor)
a) No power, lens dirty, or defective.
b) Control board dip switch 7 off.
Fill Cycle
1. Control Board
a) No power to inlet water valve.
b) No power to float switch or not reading float switch condition.
2. Inlet Water Valve
a) Screen or orifice clogged.
b) Coil winding opened.
3. Float Switch
a) Float does not move freely.
b) Defective.
4. Drain Valve
a) Valve seat clogged and water leaking.
5. Hoses
a) Disconnected.
Ice Purge Cycle
1. Control Board
a) No power to gear motor.
b) No power to compressor control relay.
2. Gear Motor
a) Blown fuse.
b) Internal protector open.
c) Defective.
Содержание FS-1001MLJ-C
Страница 56: ...56 2 FS 1022MLJ C with SRC 10J DATA PENDING ...
Страница 57: ...57 3 FS 1500MLJ C with SRC 14J DATA PENDING ...
Страница 58: ...58 B Wiring Diagrams 1 FS 1001MLJ C and FS 1022MLJ C ...
Страница 59: ...59 2 FS 1500MLJ C DATA PENDING ...
Страница 61: ...61 4 SRC 14J Condensing Unit DATA PENDING ...