PROBLEM
POSSIBLE CAUSE
REMEDY
2. Activator does not
move freely.
2. Clean Axle and its
corresponding holes or
replace Bin Control. See
“V. 3. [f] BIN CONTROL
SWITCH”.
b) Gear Motor
Protector (Circuit
Breaker)
1. Tripped.
1. Find out the cause, resolve
it, and press Reset Button
on Motor Protector.
1. Coil winding opened.
1. Replace Controller Board.
c) Gear Motor Relay
(Controller Board)
2. Bad contacts.
2. Check for continuity and
replace Controller Board.
d) Controller Board
1. Broken.
1. Replace.
1. Coil winding opened.
1. Replace.
e) Gear Motor
Protect Relay
2. Bad contacts.
2. Check for continuity and
replace.
1. Dirty Condenser fins.
1. Clean.
2. Ambient temperature
too warm.
2. Check for recommended
temperature.
3. Fan not rotating.
3. See 3 - [1] - a).
4. Refrigerant
overcharged.
4. Recharge.
5. Refrigerant line or
components plugged.
5. Clean and replace Drier.
6. Bad contacts.
6. Check for continuity and
replace.
[3] (Continued)
f) Pressure Switch
7. Loose connections.
7. Tighten.
1. Bad contacts.
1. Check for continuity and
replace Controller Board.
a) X2 Relay on
Controller Board
2. Coil winding opened.
2. Replace Controller Board.
b) Thermal Relay
1. Tripped.
1. Reset.
1. Loose connections.
1. Tighten.
2. Motor winding opened
or earthed.
2. Replace.
c) Compressor
3. Motor Protector
tripped.
3. Find out the cause of
overheat or overcurrent.
[4] Gear Motor
starts, but
Compressor
will not start or
operates
intermittently.
d) Power Supply
1. Circuit Ampacity too
low.
1. Install a larger-sized
conductor.
1. Gas leaks.
1. Check for leaks with a leak
detector. Reweld leak,
replace Drier and charge
with refrigerant. The
amount of refrigerant is
marked on Nameplate or
Label.
[5] Gear Motor
and
Compressor
start, but no ice
is produced.
a) Refrigerant Line
2. Refrigerant line
clogged.
2. Replace the clogged
component.
48
E2AH5820209