![Hoshizaki F-1002MLJZ-C Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/hoshizaki/f-1002mljz-c/f-1002mljz-c_instruction-manual_2165086007.webp)
7
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. F-450MAJ(-C)
Single Phase
Model Number
F-450MAJ(-C)
AC Supply Voltage
115/60/1
Compressor
115V 8.4RLA 50LRA
Gear Motor
115V 2.4FLA 1/4HP
Fan Motor
115V 1FLA 50W
Other
115V 0.03A
Maximum Fuse Size 15 AMPS
Max. HACR Breaker
(USA Only)
15 AMPS
Max. Circuit Breaker
(Canada Only)
15 AMPS
Minimum Circuit
Ampacity
15 AMPS
Design Pressure
HI-427PSI LO-230PSI
Refrigerant
404A 13.8 OZ.
2. F-801M_J(-C)
Single Phase
Model Number
F-801MAJ(-C)
F-801MWJ(-C)
AC Supply Voltage
115/60/1
115/60/1
Compressor
115V 7.5RLA 54.5LRA
115V 7.5RLA 54.5LRA
Gear Motor
115V 3.0FLA 200W
115V 3.0FLA 200W
Fan Motor
115V 1.0FLA 1/15HP
– – –
Other
115V 0.03A
115V 0.03A
Maximum Fuse Size 15 AMPS
15 AMPS
Max. HACR Breaker
(USA Only)
15 AMPS
15 AMPS
Max. Circuit Breaker
(Canada Only)
15 AMPS
15 AMPS
Minimum Circuit
Ampacity
15 AMPS
15 AMPS
Design Pressure
HI - 467PSI LO - 250PSI
HI - 467PSI LO - 250PSI
Refrigerant
404A 1 LB. 12 OZ.
404A 10.7 OZ.